ECG data transfer to pc interface, mini holter ecg monitor
USD $1 - $230 /Piece
Min.Order:10 Pieces
Guangzhou Joyful Technology Co., Ltd.
ECG data transfer to pc interface, mini holter ecg monitor
As a multi-functional ECG machine, mobile ECG include functions about auscultation, ECG acquisition, SpO2 and pulse rate monitoring. This instrument has ECG waveform recording and playback; oxygen value and pulse rate value could be stored and data will be uploaded to a computer to facilitate analysis of the disease.
Applicable For: hospital, community health, oxygen bar, family, before and after exercising, etc.
Compact and portable, easy to use
Display of ECG waveform, heart rate, SpO2, pulse rate, pulse waveform
Earphone output and 16 steps volume adjustable
Alarm for SpO2 and pulse rate exceeding limits
Real-time detecting, TF card data record and review
Real-time clock
Recorded data can be transferred to a PC
PC analysis software
Low power consumption
Technical specifications
Technical specifications |
Physical Characteristics |
Size: 110(length)*60(wicth)*15(height)mm Weight:100(including lithium battery) |
Environment Transport and storage |
Temperature: -10℃~ +50℃ Relative Humidity: 10% ~ 95% Atmospheric pressure: 50kPa ~ 106Kpa |
Working environment |
Temperature: 5℃~40℃ Relative Humidity: 20%~80% Atmospheric pressure: 70kPa~106kPa |
Battery type |
charging lithium battery |
Working-viktageL |
DC3.6V~DC4.2V |
Power |
≤120mA |
LCD display |
2.4"TFT, 320*240 Pixels |
Continuous running time |
7hours |
Main parameter
Measurement of auscultation volume | Heart sound range | 20Hz~230Hz |
Lung sound range | 100Hz~800Hz | |
Heart lung combination sound range | 20Hz~800Hz | |
Measurement of Heart Rate | Range | 30bpm~300bpm |
Resolution: | 1bpm | |
Accuracy | ±2bpm or ±2%(select larger) | |
Measurement of SpO2
| range | 0%~100% |
resolution | 1% | |
accuracy | 70%~100%SpO2,±2%. < 70% , unspecified. | |
Measurement of pulse rate
| Range | 30bpm~250bpm |
Resolution | 1bpm | |
Accuracy | ±2bpm or ±2%(select larger) | |
Measurement Performance in Weak filling Condition
| 0.4% pulse-filling ratio SpO2 error ±4%, Pulse rate error±2 bpm or ±2%(select larger). | |
Resistance to surrounding light
| Deviation: < ±1%.(man-made light, indoor natural light and that of darkroom) |
Product display
Our service
We offer one year free miantenance for this product
As the world's professional medical device manufacturers, our commitment to service is based on total customer satisfaction. We guarantee quick and efficient service and maintenance of our device security solutions around the world. We ensure that we will be there whenever or wherever you need us, 24 hours a day, 365 days a year. Like all Onity solutions, our products are backed by a commitment to provide superior global service with local support. we can help you work and reach your goals.