lighweight portable mobile electrocardiogram machine for testing the health
USD $1 - $230 /Piece
Min.Order:10 Pieces
Guangzhou Joyful Technology Co., Ltd.
Top seller: lighweight portable mobile electrocardiogram machine
Brief overview:
As a multi-functional ECG machine, medical device product PM-8000 ecg cario health screen machine include functions about auscultation, ECG acquisition, SpO2 and pulse rate monitoring. This instrument has ECG waveform recording and playback; oxygen value and pulse rate value could be stored and data will be uploaded to a computer to facilitate analysis of the disease.
Applicable For: hospital, community health, oxygen bar, family, before and after exercising, etc.
As a multi-functional ECG machine, medical device product PM-8000 ecg cario health screen machine include functions about auscultation, ECG acquisition, SpO2 and pulse rate monitoring. This instrument has ECG waveform recording and playback; oxygen value and pulse rate value could be stored and data will be uploaded to a computer to facilitate analysis of the disease.
Applicable For: hospital, community health, oxygen bar, family, before and after exercising, etc.
Multiple perspectives show details:
Main feature of PM-8000:
Technical specifications:
Physical Characteristics | Size: 110(length)*60(wicth)*15(height)mm Weight:100(including lithium battery) |
Environment Transport and storage | Temperature: -10℃~ +50℃ Relative Humidity: 10% ~ 95% Atmospheric pressure: 50kPa ~ 106Kpa |
Working environment | Temperature: 5℃~40℃ Relative Humidity: 20%~80% Atmospheric pressure: 70kPa~106kPa |
Batterytype | charging lithium battery |
Working-viktageL | DC3.6V~DC4.2V |
Power | ≤120mA |
LCD display | 2.4"TFT, 320*240 Pixels |
Continuous running time | 7hours |
(1) Measurement of auscultation volume | Heart sound range: 20Hz~230Hz Lung sound range: 100Hz~800Hz Heart lung combination sound range: 20Hz~800Hz |
(2)Measurement of Heart Rate | Range: 30bpm~300bpm Resolution: 1bpm Accuracy: ±2bpm or ±2%(select larger) |
(3)Measurement of SpO2 | range: 0%~100% resolution: 1% accuracy: When the SpO2 measurement range is 70%~100%, the permission of absolute error is ±2%. Below 70% unspecified. |
(4)Measurement of pulse rate | Range: 30bpm~250bpm Resolution: 1bpm Accuracy: ±2bpm or ±2%(select larger) |
(5) Measurement Performance in Weak filling Condition | SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%(select larger). |
(6) Resistance to surrounding light | The deviation between the value measured in the condition of man-made light and indoor natural light and that of darkroom is less than ±1% |