Temperature Controller CD101
USD $11 - $14 /Piece
Min.Order:100 Pieces
Yueqing Xinyang Automation Equipment Co., Ltd.
CD series Digital Temperature Controller
♦ Industrial standard microcomputer processor
♦ Auto adjusting function
♦ Big screen LED display
♦ Heating/Cooling control
♦ Digital communication
Model Name:
(1)Outline dimension | See the outline dimension picture |
|
(2)Control Mode | F:PID operation and auto calculating (reverse operation) | D:PID operation and auto calculating(Forward operation) |
W: heating/cooling PID operation and auto calculating(cooling water)*1 | A: heating/cooling PID operation and auto calculating(cooling wind)*1 | |
(3)Input mode | Refer to Input Range Table |
|
(4)Range Code | Refer to Input Range Table |
|
(5)First control output(OUT1) (Heating side) | M: Relay contact output | 8: Current output(IC4-20mA) |
V: Voltage impulse output | G: Thyratron driving & triggering output | |
T: Thyratron output |
| |
(6)Second controloutput (OUT2) (Cooling side)*2 | No mark: when the control mode is F or D |
|
M: Relay contact output | T: Thyratron output | |
V: Voltage impulse output | 8: Current output(IC 4-20mA) | |
(7)First alarm (ALM1)
(8)Second alarm (ALM2)*2
| N: no alarm |
|
A: Upper-limit deviation alarm | J: lower-limit input alarm | |
B: Lower-limit bias alarm | K: Standby upper-limit input alarm attached | |
C: Upper/lower limit bias alarm | L: Standby lower-limit input alarm attached | |
D: alarm in area | P: Heater line breakage alarm(CTL-6)*3 | |
E: Standby upper-limit bias alarm attached | S: Heater line breakage alarm(CTL-12)*3 | |
F: Standby lower-limit bias alarm attached | R: Control line breakage alarm *4 | |
G: Standby upper/lower limit bias alarm | V: Upper-limit setting alarm | |
H: Upper-limit input value alarm | W: Lower-limit set value alarm | |
(9)Communication*5 | N: No communication |
|
(10)Water-proof/dust-proof | N: no water-proof/dust-proof |
|
Refer to Input Range Table
| Input type | Set range | Input type | Set range | |||
(TC) Thermocouple Input(TC) | K | 0 to 1372°c(0 to 2502°F) | J | 0 to 1200°c(0 to 2192°F) | |||
R | 0 to 1769°c(0 to 3216°F) | S | 0 to 1769°c(0 to 3216°F) | ||||
B | 0 to 1820°c(0 to 3308°F) | E | 0 to 1000°c(0 to 1832°F) | ||||
N | 0 to 1300°c(0 to 2372°F) | T | -199.9 to +400.0°c(-199.9 to +752.0°F) | ||||
W5Re/W26Re | 0 to 2320°c(0 to 4208) | PL | 0 to 1390°c(0 to 2534°F) | ||||
L | 0 to 900°c(0 to 1652°F) | U | -199.9 to +600.0°c(-199.9 to +999.9°F) | ||||
RTD Input | Pt100Ω(JIS/IEC) | -199.9 to +649.0°c (-199.9 to +999.9°F) | JPt100Ω(JIS) | -199.9 to +649.0°c (-199.9 to +999.9°F) | |||
Voltage input | 0 to 5V DC | 1 to 5V DC | -1999 to +9999(programmable range) | ||||
Current input | 0 to 20mADC | 4 to 20mADC | -1999 to +9999(programmable range) |