BIOBASE 2000 Automated Elisa Processor/ Elisa Analyzer system (skype: fangfeimengxiang876)
USD $9,000 - $13,000 /Set
Min.Order:1 Set
Zhangqiu Meihua International Trading Co., Ltd.
BIOBASE 2000 Automated Elisa Processor/ Elisa Analyzer system
Testing Range:
1. TORCH SERIES 4. THYROID AUTOIMMUNITY SERIES
Toxo, RV, CMV, HSV etc. T3, T4, FT3, TSH etc
2. HEPATITIS SERIES 5. ENDOCRINE SERIES
HAV, HBV, HCV, HDV, HEV etc. E2, E3, LH, FSH, HCG, Pro, PRL etc.
3. VENEREAL SERIES 6. TUMOR MARKER SERIES
HIV, TP, MP, CT etc. CEA, AFP, PSA F-PSA, CAL9-9, CAL 25, CA15-3, CA242.
Technical Specifications:
Model | Biobase2000 | |
Type | Fully automated ELISA processor
| |
Pipetting Specifications | Syringes | 1000ul volumes,1ul step resolution |
sample rack | 13*13 | |
Pipetting area | 4 plate | |
Pipetting probe | 2 probes | |
Dilution rack | 144 positions | |
Sample pipetting unit | Sample rack | 169-12 mm sample tubes |
Dilution rack | 144 positions | |
Sample primary tubes | 13×75mm | |
pipetting system | Metal needle | |
Pipetting volumes | 8ul~1000ul | |
pipetting precision | (10ul) CV<5% | |
Time to dispense | 15 minutes(typical)^100ul of 96 reagents to plate from sample tubes or dilution tubes | |
Dispensing system | 1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000ul, continuous flow washing station | |
Liquid level sensing | electronic | |
Reagent pipetting unit | Reagent racks | 10 special reagent racks,2 general reagent racks |
Removable trays | modular racks to hold calibrators, controls and reagents for 10 methods on line | |
Pipetting volumes | 8ul~1000ul | |
pipetting precision | (100ul )CV≤0.2% | |
Time to dispense | 2 minutes(typical)^100ul of 96 reagents to plate from reagent bottle | |
Dispensation | from 8 µl to 1000 µl by 1 µl step, inaccuracy ± 1% at 100 µl | |
Washing unit | Programmable | Yes(options & parameters) |
Wash containers | 4 wash buffers at 2.0L, with level-sensing | |
Waste containers | 10L with waste full sensor | |
Washing system | two 8 nozzle manifolds, one to dispense and the other one to aspirate; | |
Washing residual volume | <2µl | |
Plate washing inaccuracy | CV < 5 % at 300µl | |
Reading unit | Reading system | 8 independent photometric channels with mono and bichromatic reading capability |
Photometric range | 0.000 to3.000 OD | |
Spectral range | 400-700nm | |
Optical filters | 2 precision filters (450and 630nm); 2 more on request (4 filters max, 400-700nm) | |
Reading inaccuracy | inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD | |
Incubation unit | Incubators | 4 independent units |
Programmable | Yes | |
Temperature range | RT to 45 °C | |
Temperature accuracy | ±0.2°C | |
Adjustment step size | ±0.1°C | |
Software unit | Operative systems | Windows XP or Windows 7 |
Connection | LIS interface capability, work list import from Host computer | |
Function application | work list set up, patient reports and result filing; calibration curve storage for each carried out test | |
Data reduction | cut-off (qualitative) | |
Management system | Minimum requirements | 250 MB free space hard disk; CD-Rom reader; 2 GB RAM; Intel Pentium Dual Core or equivalent; VGA 1024 x 768 16 million colours; 1 free USB |
Suggested requirements | 4 GB RAM; Intel Core 2 Duo E6500 series processor or equivalent | |
Instrumentation dimensions | Depth | 750mm |
Height | 770mm | |
Width | 1130mm | |
Weight | 120kg | |
Electrical requirements | Voltage | 230 or 115 VAC |
Frequency | 50-60 Hz | |
Power | 350 W |