BIOBASE-EL10A Automatic ELISA Plate Analyser,ELISA Reader and Washer
USD $1,400 - $1,500 /Set
Min.Order:1 Set
Zhangqiu Meihua International Trading Co., Ltd.
BIOBASE-EL10A Automatic ELISA Plate Analyser,ELISA Reader and Washer
1.Good repeatability: CV≤0.3%
2.Good stability: ≤ ±0.003
3. Having vibration plate function with 5 vibration plate speeds adjustable and 0 ~ 255s time adjustable.
4. Large LCD touch screen display, able to monitor, save and print testing results directly.
1. Medical Fields: (Elisa method testing items)
Hepatitis test series: HAV, HBV, HCV, HDV, HEV, HGV,AIDS (HIV), Syphilis (TP), TORCH, Thyroid hormone series, Sex hormone test series
2. Food and feed Fields:
Chloramphenicol, Aflatoxin, Melamine, Pesticide residue, etc.
3. Laboratory Fields:
The ingredient content of lab experiment items, etc.
Main Specification:
Main specification | |
Plate type | 48-hole,96-hole microplates or bars. |
Light source | Single light source,Halogen tungsten Lamp,with an average life expectancy ≥5000 hours |
Detector | Silicon photocell |
Wave length | 400nm-750nm |
Optical Filter | Standard 405,450,492,630nm , other wavelengths can be optional |
Absorbance range | 0.000-4.000Abs |
Measurement mode | Single-,dual-wavelength automatic measurement |
Calculation mode | Open type qualitative determination and quantitative analysis |
Repeatability | CV ≤0.3% |
Stability | ≤±0.003Abs |
Resolution | 0.001Abs |
Reading speed | ≤6s/96well plate,single wavelength |
Vibration plate mode | 5 strength(from weak to strong) can be set,time 0-240s adjustable |
Display | Large-screen LCD display,touch screen input |
Interface | USB printer interface ,RS232 |
Printer (optional) | External wide-line printer |
power supply | AC220V±22V,50±1Hz |
Fully automated ELISA analyzer(BIOBASE1000)
Model | Biobase1000 |
Type | Fully automated ELISA analyzer |
Sample racks | 60 or 80 – 12 mm sample tubes or 40 - 16 mm sample tubes |
Dilution rack | 92 positions |
Reagents holder | modular racks to hold calibrators, controls and reagents for 8 methods on line |
Liquid reservoirs | external tanks equipped with level sensors; 2 washing buffer |
Microtiter plates | 2 plates (96 wells) with incubation capability, from room temperature to 45 °C |
Dispensing system | 1 aspirating-dispensing probe with X-Y-Z movement; dilution system with a syringe of 1000 μl, continuous flow washing station |
Washing system | two 8 nozzle on line manifolds with automatic adaptation for the different micro-plates height |
Washing Residual volume | < 3μl |
Washing inaccuracy | CV < 5 % with 300 μl |
Readingsystem | 8 independent photometric channels for mono and bichromatic reading |
Optical filters | 2 filters (450 and 630 nm); 2 more on request (max 4 filters) |
Readinginaccuracy | ± 1% from 0.000 to 1.500 OD ± 2% from 1.500 to 3.000 OD |
Dispensation | from 8 ml to 1000 ml with 1μl resolution; inaccuracy ±1% with 100 μl |
Software | Windows 98 and XP operating system, to set up the work list, patient reports and results filing; calibration curves storage for each carried-out test |
Connection | LIS interface capability, work list set up from Host computer. Capability of connecting more instruments to a single PC. |
Power Supply | 200/110 VAC, 50-60 Hz |
Dimension | 620 x 820 x 720 |
Weight | 80 Kg |
Fully automated ELISA processor (BIOBASE2000)
Model | BIOBASE2000 | |
Sample pipetting unit | Sample rack | 24 sample tubes/rack, at most 25 racks |
Primary sample tubes | 11.5-13mm | |
Pipetting | 8ul~1000ul, (10ul) CV<5% | |
Time to dispense | 15 minutes (typical)^100ul of 96 samples to plate from sample tubes or dilution tubes. | |
Dispensing system | 1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000ul, continuous flow washing station. | |
Reagent pipetting unit | Reagent racks | 2 reagent tanks(60ml)/ rack, at most 25 racks |
QC racks | 24 positions/QC rack, at most 25 racks | |
Pipetting | 8ul~1000ul,1ul stepping, | |
pipetting precision | (100ul )CV≤0.5% | |
Time to dispense | 2 minutes(typical)^100ul of 96 reagents to plate from reagent bottle | |
Washing unit | Programmable | Yes(options & parameters) |
Wash containers | 4 wash buffers at 2.0L, with level-sensing | |
Waste containers | 10L with waste full sensor | |
Washing system | two 8 nozzle manifolds, one to dispense and the other one to aspirate; | |
Washing residual | <2μl | |
Reading unit | Reading system | 8 independent photometric channels with mono and bichromatic reading capability |
Photometric range | 0.000 ~3.000 OD | |
Spectral range | 400-700nm | |
Optical filters | 2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm) | |
Reading inaccuracy | inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD | |
Incubation unit | Incubators | 4 independent units |
Programmable | Yes | |
Temperature range | RT to 45 °C | |
Temperature accuracy | ±0.5℃ | |
Temperature staility | ±0.5℃ | |
Software unit | Software system | Windows XP or Windows 7 or above, LIS system available, realize two-way data communications |
Function application | work list set up, patient reports and result filing; calibration curve ,storage for each carried out test | |
Data reduction | cut-off (qualitative) | |
Physical Specification | Power Supply | AC220V+ 10%,50/60Hz,450W |
Instrument Dimension | 110*72*70cm (L*W*H) | |
Instrument Weight | 100kg | |
Package Dimension | 138*91*98cm(L*W*H) | |
Total Weight | 150kg |
Certificate:
Contact person:
BIOBASE Meihua Trading Co.Ltd(BIOBASE Group)
Address:NO.51 South Gongye Road,Jinan,China
Viber/WhatsApp: +86 15553137962
Skype:fangfeimengxiang876