FLS2-700 oil tank level measurement transducer factory
FLS2-700 oil tank level measurement transducer factory
FLS2-700 oil tank level measurement transducer factory
FLS2-700 oil tank level measurement transducer factory
FLS2-700 oil tank level measurement transducer factory
FLS2-700 oil tank level measurement transducer factory

FLS2-700 oil tank level measurement transducer factory

USD $10 - $70 /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
tianjin shanghai qingdao alxn
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Beijing, China
Brand Name:
oil tank level measurement
Model Number:
oil tank level measurement
Usage:
Level Sensor
Theory:
Capacitance Sensor
Output:
Other, analog and digital sensor

Beijing Hengtop Technology Co., Ltd.

Business Type: Trading Company
Beijing China
Main Products: Sensor ,GPS Tracker ,Gauge

Product Details

  FLS2-700 oil tank level measurement transducer factory

 

1. New fuel level sensor
2. High precision
3.Output: 0.5 ~ 4.5V, 0~5V, can be customized;

 

Applications

Product Description

 

Fuel level sensor / water level sensor / level / indicator / probe / transducer / gauge / needle / transmitter / stick

Capacitance fuel Sensor / Capacitance Pressure Transducer / Capacitance Pressure Transmitter

Oil level measuring for automobile oil tanks, tankers and oil depots

Liquid level measurement / Anti fuel theft / fuel consumption management / liquid level sensing

Water, fuel, liquid tank level sensor / sensing

FLS2-700 oil tank level measurement transducer factory

 

Unique Features

  • Calibrator for calibration
  • Cuttable on spot
  • SEA 5bolts mount
  • Outputs: RS232/485; 0-5v; 0.5-4.5V
  • Capacitance principle
  • 10-32V power supply
  • High precision
  • Applicable to non-conductive medium

 

Introduction

 The level sensor enjoy multi-innovation technologies, with capacitance as the sensitive element, GB sensor series continuous detects the height of the fuel level with less than 1mm resolution. Sensor length can

also be shorter to fit tanks with different heights. GB sensor can replace the original fuel level sensor on vehicles and connects with oil gauge. With wide range of voltage input, it has no limitation to input voltage.

 

Main Features

Spcification

Power supply10-32V
Output0.5 ~ 4.5V, 0~5V, RS232,can be customized;
Resolution≤1mm
Operational Temperature- 40 ~ +85°C
Impurity filter

Helps to minimize grease and
foreign particle build ups, thereby ensuring a stable
signal output;

Compatible Medium

Diesel, biodiesel, gasoline, kerosene (Not applicable to conducting medium)

Sensor length10-150cm
Signal refreshing rate5s each time (Custom)
Maximum operating current< 15mA
Protection rankIP65
Mode of connection

Pin1: VCC;
Pin2: V out (0.5~4.5V);
Pin3: GND;
Pin4:Connect to calibrator;

Pin5:Connect to calibrator;
Pin6:Connect to calibrator;

 

Tips on calibaration:

1. Calibrator:
Calibrator must couple with the sensor, and it has 12V/ 23A battery inside.
Red light is the power light. If the light isn't on when switch on, battery replacement is needed;
Green light is the calibration light. Full/ Empty button is showed in above picture.
Note: Calibration is necessary before using the sensor due to different fuel types;

FLS2-700 oil tank level measurement transducer factory

FLS2-700 oil tank level measurement transducer factory


2. Length adjustment and Calibrator:
2.1 Adjustment of sensor length
Aluminum tube at the bottom can be shorter according to different requirements from customers. Steps are as follows:
2.1.1 Customer specifies the sensor length according to the needs;
2.1.2 Cut the unwanted part with steel saw;
2.1.3 Get rid of the burrs and the debris at the cutting area with blade or a
screwdriver to avoid short circuit.
2.1.4 Take down the filter unit, take out the plug, and assemble the plug in the aluminum tube, then assemble the filter.


3. Calibration of the fuel level sensor
Calibration of the fuel sensor is calibration of the full level and empty level. The fundamental principle is to record a full value and empty value in the fuel sensor when tank is full and empty; defining the positions of fuel is full and empty in the tank. The electrical signal changes as the fuel level changes, calculating the height of the fuel level.


Note: when the fuel sensor becomes shorter, it shall be recalibrated. Calibration to empty level and full level is related to the medium and the fuel level, instead of volume of the tank, so this operation can be operated in room (make a container, full filled with diesel,simulation of the tank). Calibration of full level shall go first, then the empty level, or else, it is impossible for the sensor to enter thesetting mode.


4. Calibration of full level
Full fill the tank, put sensor into the tank, wait for about 30s till the aluminum tube of the sensor is full of fuel, then press the “full” button on the calibrator for 5 seconds till the green LED light slowly flickers, it indicates that calibration enters full level mode. The green LED light is off after about 10 seconds and it indicates that the calibration of the full level is OK.


5. Calibration of the empty level
Take the sensor out of the tank; put it outside of the tank. When all the fuel flows out of the sensor, press the “empty” button for 5 seconds till the green LED light flickers fast, it indicates that calibration enters empty level mode. The green LED light is off after about 10 seconds and it indicates that the calibration of empty level is OK.


6. Calibration completion

Disconnect the calibrator after calibration is done. Connect Pin 1 and Pin 3 on sensor with power, calibration becomes effective when sensor is power on.
Note: If press the wrong button during operation, you can switch off the calibrator and exit the mode and readjust.


7. Inspection
When calibration of the full level and empty level is done, inspect the output signal of the sensor:
Full level: V out is 5V
1/2 level: V out is 2.5V;
Empty level: V out is 0V.
If the output signal meets the values listed above, it means calibration is OK and normal operation of the sensor. Otherwise, please check the mode of connection and recalibrate it.

FLS2-700 oil tank level measurement transducer factoryFLS2-700 oil tank level measurement transducer factory

FLS2-700 oil tank level measurement transducer factory

 

 

Packaging & Shipping

 

 

FLS2-700 oil tank level measurement transducer factory

 

FLS2-700 oil tank level measurement transducer factory

 

 

 

 

 

Our Services

 

 

After Sale Service Of Sensor

FLS2-700 oil tank level measurement transducer factory 

 

 

Company Information

 

 

Our Company

FLS2-700 oil tank level measurement transducer factory

FLS2-700 oil tank level measurement transducer factory 

 

 

 

 

 

 

Contact Supplier

Ms. Lisa Cao Manager Chat Now
Telephone
86-10-84176686
Mobile
13146348272
Address
Xiliu Mid-street ,Sanjianfang ,Chaoyang District ,Beijing China Beijing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Active Components > Sensors
Categories
Hi~