Summary for Four Channel Temperature Indicator AI-704M
AI-702M, AI-704M and AI-706M multi-channel indicators provide 1-2, 1-4, 1-6 channels of independent process indications, and are ideal for the measurement, indication, alarm, calculation and retransmission of temperature, pressure, flow, level and humidity etc.
Main Features for 4 Channel Temperature Indicator AI-704M Support Alarm, Transmission, Communication
Technical Specifications for Four Channel Temperature Indicator AI-704M
1. Input:
Thermocouples: (with J1 module): K, S, R, E, J, T, B, N and WRe5-WRe26
Two-wire RTDs: (with J2 module that supports 2 inputs): PT100, Cu50, 0~80 ohm, 0~400 ohm
Three-wire RTDs: (with J0 module that supports 1 inputs): PT100, Cu50, 0~80 ohm, 0~400 ohm
Linear mV voltages: (with J1 module) 0~20mV, 0~60mV, 0~100mV, 0~1V
Linear voltage: (with J3 module) 0~1V, 0~3V, 0~5V, 1~5V etc.
Linear current: (with J4 module) 0~12mA, 0~20mA, 4~20mA etc.
Square root extraction calculation input: (with J3 voltage or J4 current input module) 1~5V, 4~20mA etc.
Two-wire transmitter inputs: (with J5 module that provides 24VDC power supply) Connect to 4~20mA two wires transmitter
2. Maximum lead wire resistance for RTD input:
2-wire type RTDs:
2 ohm for Pt100 or 0~400 ohm input ;1 ohm for Cu50 and 0-200 ohm input;
3-wire type RTDs:
5 ohm
3. Measurement range:
K(0~1300℃), S(0~1700℃), R(0~1700℃), T(-200~+350℃), E(0~1000℃), J(0~1200℃), B(0~1800℃), N(0~1300℃), WRe5-WRe26(0~2300℃),
Pt100(-200~+800℃), Cu50(-50~+150℃)
Linear input:-1999~+9999 set by user
4. Measurement accuracy: ±0.2%FS±1digit / ±0.3%FS±1digit (only for Cu50)
Note 1: For thermocouple inputs with internal cold junction compensation, 1℃ CJC error should be taken into consideration. For those with Cu resistor, ice point or thermostat bath compensation, the accuracy is as above.
Note 2: Accuracy is not guaranteed between 0 and 600℃ for type B thermocouple input.
5. Temperature drift: ≤0.01%FS/℃ (typical 50ppm/℃)
6. Electromagnetic compatibility: IEC61000-4-4, ±4KV/5KHz; IEC61000-4-5, 4KV
7. Isolation withstanding voltage: Between power, relay contact and signal terminals ≥ 2300VDC; Between isolated eletroweak signal terminals ≥ 600VDC
8. Response time: ≤1.5 seconds(if digital filter parameter is set as 0 or 1)
9. Automatic pilot time interval: Approx. 1.2s or 2s configurable
10. Alarm function: High and low alarm, configurable separately for each channel
11. Alarm output:
Relay contact output(NO or NC):250VAC/1A or 30VDC/1A
No contact discrete output(NO or NC):250VAC/0.3A(transient current 1A)
12. Power supply: 100~240VAC/50Hz, 24VDC
13. Power consumption: ≤6W
14. Work ambience: Temperature -10~+60℃, Humidity ≤ 90%RH
Terminal Layout and Wiring for 4 Channel Temperature Indicator AI-704M Alarm, Transmission, Communication
Ordering Code Definition for AI-704M
The ordering code of AI-702M/704M/706M series instrument is made up of 9 parts. For example:
AI-706M A J1 J2 J5 L5 L5 S - 24VDC
1 2 3 4 5 6 7 8 9
Above code symbols a AI-706M instrument with: front panel dimension 96*96mm, 2 thermocouple inputs, 2 two-wire RTD inputs, 2 current inputs, 4 alarm relay outputs, RS485 communication interface and the supply power is 24VDC. The explanation for each code is below:
Part 1 Model of the instrument
AI-702M/704M/706M respectively indicate 2, 4, 6 channels indicator.
Part 2 Dimension
The depth of the instrument is about 13.2mm(foreside)+100mm(rearward).
Size | Front Panel (W*H) | Cut Out (W*H) | Remarks |
A | 96*96mm | 92*92mm |
|
B | 160*80mm | 152*76mm | |
C | 80*160mm | 76*152mm | |
E | 48*96mm | 45*92mm | |
E5 | 48*96mm | E5 is no panel design. It's installed on DIN rail and programmed by connecting to external display or computer. | |
F | 96*48mm | 92*45mm |
Part 3~8 Shows the module type installed on sockets
N: No module installed
J0: 1 channel three-wire RTD, thermocouple or mV voltage input
J1: 2 channel two-wire thermocouple or mV voltage inputs
J2: 2 channel two-wire RTD inputs
J3: 2 channel voltage inputs of 0-1V, 0-3V, 0-5V or 1-5V etc.
J4: 2 channel current inputs of 0-12mA, 4-20mA, 0-20mA etc.
J5: 2 channel two-wire transmitter provided 24VDC power supply.
I5: 2 channel on-off signal inputs, drycontact
L1: Single relay contact (NO+NC) output. (30VDC/2A, 264VAC/2A)
L2: Single relay contact (NO+NC) output. (30VDC/1A, 264VAC/1A)
L4: Single relay contact (NO+NC) output. (30VDC/2A, 264VAC/2A)
L5: Dual relay contact (NO) outputs. (30VDC/2A, 264VAC/2A)
W1: 1 channel thyristor normal open output. (“Burnt proof” technology, able to stand 0.3A continuous current or 1A transient current)
G: 1 SSR voltage output (12VDC/30mA)
G5: 2 SSR voltage outputs (12VDC/30mA)
S: Photoelectric isolated RS485 interface
S4: Photoelectric isolated RS485 interface with isolated power supply.
X3: Photoelectric isolated linear current output
X5: Photoelectric isolated linear current output with its own isolated power supply.
V5: Photoelectric isolated 5VDC/50mA power supply for transmitter.
V10: Photoelectric isolated 10VDC/50mA power supply for transmitter.
V12: Photoelectric isolated 12VDC/50mA power supply for transmitter.
V24: Photoelectric isolated 24VDC/50mA power supply for transmitter.
Part 9 Shows power suppl
Null indicates 100~240VAC power supply and "24VDC" indicates 20~32VDC/AC power.
Front Panel and Operation for AI-704M 4 Channel Indicator Alarm, Transmission, Communication
You will get:
A piece of temperature indicator;
A paper of user manual;
5-year warranty card and Quality Approval card;
A lable of units;
A pair of installaton brackets;
Nice package carton box with Yudian logo.
If you are interested in our products or have any questions, please do not hesitate to contact us.