Two Channel Temperature Indicator AI-702M High Quality Fast Delivery
USD $10 - $100 /Unit
Min.Order:3 Units
Xiamen Yudian Automation Technology Co., Ltd.
Summary for Two Channel Temperature Indicator AI-702M High Quality Fast Delivery
AI-702M, AI-704M and AI-706M multi-channel indicators provide 1-2, 1-4, 1-6 channels of independent process indications, and are ideal for the measurement, indication, alarm, calculation and retransmission of temperature, pressure, flow, level and humidity etc.
Main Features for Two Channel Temperature Indicator AI-702M High Quality Fast Delivery
Technical Specifications for Two Channel Temperature Indicator AI-702M High Quality Fast Delivery
1. Input:
Thermocouples: (with J1 module): K, S, R, E, J, T, B, N and WRe5-WRe26
Two-wire RTDs: (with J2 module that supports 2 inputs): PT100, Cu50, 0~80 ohm, 0~400 ohm
Three-wire RTDs: (with J0 module that supports 1 inputs): PT100, Cu50, 0~80 ohm, 0~400 ohm
Linear mV voltages: (with J1 module) 0~20mV, 0~60mV, 0~100mV, 0~1V
Linear voltage: (with J3 module) 0~1V, 0~3V, 0~5V, 1~5V etc.
Linear current: (with J4 module) 0~12mA, 0~20mA, 4~20mA etc.
Square root extraction calculation input: (with J3 voltage or J4 current input module) 1~5V, 4~20mA etc.
Two-wire transmitter inputs: (with J5 module that provides 24VDC power supply) Connect to 4~20mA two wires transmitter
2. Maximum lead wire resistance for RTD input:
2-wire type RTDs:
2 ohm for Pt100 or 0~400 ohm input ;1 ohm for Cu50 and 0-200 ohm input;
3-wire type RTDs:
5 ohm
3. Measurement range:
K(0~1300℃), S(0~1700℃), R(0~1700℃), T(-200~+350℃), E(0~1000℃), J(0~1200℃), B(0~1800℃), N(0~1300℃), WRe5-WRe26(0~2300℃),
Pt100(-200~+800℃), Cu50(-50~+150℃)
Linear input:-1999~+9999 set by user
4. Measurement accuracy: ±0.2%FS±1digit / ±0.3%FS±1digit (only for Cu50)
Note 1: For thermocouple inputs with internal cold junction compensation, 1℃ CJC error should be taken into consideration. For those with Cu resistor, ice point or thermostat bath compensation, the accuracy is as above.
Note 2: Accuracy is not guaranteed between 0 and 600℃ for type B thermocouple input.
5. Temperature drift: ≤0.01%FS/℃ (typical 50ppm/℃)
6. Electromagnetic compatibility: IEC61000-4-4, ±4KV/5KHz; IEC61000-4-5, 4KV
7. Isolation withstanding voltage: Between power, relay contact and signal terminals ≥ 2300VDC; Between isolated eletroweak signal terminals ≥ 600VDC
8. Response time: ≤1.5 seconds(if digital filter parameter is set as 0 or 1)
9. Automatic pilot time interval: Approx. 1.2s or 2s configurable
10. Alarm function: High and low alarm, configurable separately for each channel
11. Alarm output:
Relay contact output(NO or NC):250VAC/1A or 30VDC/1A
No contact discrete output(NO or NC):250VAC/0.3A(transient current 1A)
12. Power supply: 100~240VAC/50Hz, 24VDC
13. Power consumption: ≤6W
14. Work ambience: Temperature -10~+60℃, Humidity ≤ 90%RH
Terminal Layout and Wiring for Two Channel Temperature Indicator AI-702M
Ordering Code Definition for Two Channel Temperature Indicator AI-702M
The ordering code of AI-702M/704M/706M series instrument is made up of 9 parts. For example:
AI-706M A J1 J2 J5 L5 L5 S - 24VDC
1 2 3 4 5 6 7 8 9
Above code symbols a AI-706M instrument with: front panel dimension 96*96mm, 2 thermocouple inputs, 2 two-wire RTD inputs, 2 current inputs, 4 alarm relay outputs, RS485 communication interface and the supply power is 24VDC. The explanation for each code is below:
Part 1 Model of the instrument
AI-702M/704M/706M respectively indicate 2, 4, 6 channels indicator.
Part 2 Dimension
The depth of the instrument is about 13.2mm(foreside)+100mm(rearward).
Size | Front Panel (W*H) | Cut Out (W*H) | Remarks |
A | 96*96mm | 92*92mm |
|
B | 160*80mm | 152*76mm | |
C | 80*160mm | 76*152mm | |
E | 48*96mm | 45*92mm | |
E5 | 48*96mm | E5 is no panel design. It's installed on DIN rail and programmed by connecting to external display or computer. | |
F | 96*48mm | 92*45mm |
Part 3~8 Shows the module type installed on sockets
N: No module installed
J0: 1 channel three-wire RTD, thermocouple or mV voltage input
J1: 2 channel two-wire thermocouple or mV voltage inputs
J2: 2 channel two-wire RTD inputs
J3: 2 channel voltage inputs of 0-1V, 0-3V, 0-5V or 1-5V etc.
J4: 2 channel current inputs of 0-12mA, 4-20mA, 0-20mA etc.
J5: 2 channel two-wire transmitter provided 24VDC power supply.
I5: 2 channel on-off signal inputs, drycontact
L1: Single relay contact (NO+NC) output. (30VDC/2A, 264VAC/2A)
L2: Single relay contact (NO+NC) output. (30VDC/1A, 264VAC/1A)
L4: Single relay contact (NO+NC) output. (30VDC/2A, 264VAC/2A)
L5: Dual relay contact (NO) outputs. (30VDC/2A, 264VAC/2A)
W1: 1 channel thyristor normal open output. (“Burnt proof” technology, able to stand 0.3A continuous current or 1A transient current)
G: 1 SSR voltage output (12VDC/30mA)
G5: 2 SSR voltage outputs (12VDC/30mA)
S: Photoelectric isolated RS485 interface
S4: Photoelectric isolated RS485 interface with isolated power supply.
X3: Photoelectric isolated linear current output
X5: Photoelectric isolated linear current output with its own isolated power supply.
V5: Photoelectric isolated 5VDC/50mA power supply for transmitter.
V10: Photoelectric isolated 10VDC/50mA power supply for transmitter.
V12: Photoelectric isolated 12VDC/50mA power supply for transmitter.
V24: Photoelectric isolated 24VDC/50mA power supply for transmitter.
Part 9 Shows power suppl
Null indicates 100~240VAC power supply and "24VDC" indicates 20~32VDC/AC power.
Front Panel and Operation for Two Channel Temperature Indicator AI-702M
You will get:
A piece of temperature indicator;
A paper of user manual;
5-year warranty card and Quality Approval card;
A lable of units;
A pair of installaton brackets;
Nice package carton box with Yudian logo.
If you are interested in our products or have any questions, please do not hesitate to contact us.