Explosion-proof RTD Temperature Transmitter
USD $125 - $350 /Piece
Min.Order:1 Piece
Main tech data
Platinum thermal resistance accuracy: class B
Graduation: Pt100. (The resistance value in 0℃) R=100~0.12ohm(B)
Allowable deviation delt t(℃): ±(0.30+0.005t)(B)
Input: thermocouple: K, E; Thermal resistor: Ptl00
Output: It is linear with electric signal of thermal resistor or millivolt signal of thermocouple within DC 4~20mA signal , linear with temperature of thermal resistance or thermocouple.
Note: The output and input of isolated temp transmitter is isolated, the isolated voltage is 0.5kv. Basic error: compute formulas delt=delt 1+delt 2,
delt 1 is allowed deviation of thermocouple
delt 2 is basic error of transmitter ±0.5%FS
Transmission mode: two wire system.
Working voltage: Lowest 12V, highest 35V, and rated 24V
Load: Limit load calculation as follows,
R1(max)=50×(Vmin-12)
(The load resistance can be selected from 0~600 ohm in 24V, and the rated load is 250 ohm)
a. Ambient temp: -25℃~80℃ (not higher than 70℃ in dangerous place)
b. Relative humidity: 5%~95%
c. Mechanical vibration: f≤55Hz, swing<0.5mm
d. No corrosive medium around
Explosion proof class
(Explosion proof type):dIIBT4 dIIBT6 or dIICT4 dIICT6
(Intrinsic safe):ibII BT4, ia IIBT4,iaIICT6(multiple)
Models of related equipment are MTL728,Z928,L8928.
Housing: IP65
Model
W | B | W | specifications |
| ||||||||||||
|
| Temperature |
|
| General type | |||||||||||
R |
| Thermal resistance | ||||||||||||||
Z |
|
| Thermocouple | |||||||||||||
| - |
|
| |||||||||||||
| 2 |
| Output and corresponding temperature in linearity | |||||||||||||
4 |
| Output and corresponding input signal in linearity | ||||||||||||||
Output | 0 |
| General type | |||||||||||||
Thermocouple |
|
| ||||||||||||||
1 |
| E NiCr-CuNi | ||||||||||||||
2 |
| K NiCr-NiSi | ||||||||||||||
3 |
| S PtRh10-Pt | ||||||||||||||
4 |
| B PtRh30-PtRh6 | ||||||||||||||
5 |
| T Cu-CuNi | ||||||||||||||
6 |
| J Fe-CuNi | ||||||||||||||
8 |
| N NiCrSi-NiSi | ||||||||||||||
Thermal resistance |
|
| ||||||||||||||
1 |
| Cu50 | ||||||||||||||
4 |
| Pt100 | ||||||||||||||
Sensor | 7 |
| Isolation type with temperature element | |||||||||||||
8 |
| Non-isolation type with temperature element | ||||||||||||||
Circuit | 0 |
| Standard | |||||||||||||
1 |
| Smart | ||||||||||||||
2 |
| Digital Display | ||||||||||||||
3 |
| Needle type | ||||||||||||||
4 |
| Smart display | ||||||||||||||
5 |
| Smart needle | ||||||||||||||
6 |
| With HART | ||||||||||||||
| / |
|
| |||||||||||||
| 2 |
| Fixed thread | |||||||||||||
4 |
| Fixed flange | ||||||||||||||
6 |
| Fixed thread taper tube | ||||||||||||||
8 |
| Female thread | ||||||||||||||
9 |
| Thermowell tube | ||||||||||||||
Mounting | 4 |
| Explosion-proof | |||||||||||||
Junction box | S |
| PT100 | |||||||||||||
0 |
| Thermocouple | ||||||||||||||
1 |
| insulation(sheathed) | ||||||||||||||
2 |
| Shell(sheathed) | ||||||||||||||
| 3 |
| Tri-type | |||||||||||||
| K |
| Sheathed | |||||||||||||
| d | Explosion-proof | ||||||||||||||
i | Intrinsic safe | |||||||||||||||
|
| |||||||||||||||
S | B | W | * | - | * | * | * | * | / | * | * | * | * | * | * |
|
SBW Series explosion-proof intrinsic safe transmitter with thermocouple or RTD is field mounting type instrument. It combines the thermocouple (resistance) with the transmitter as a whole, directly measures the temp of vapor, gas and liquid in a variety of industrial temperature from -200 to 800℃, and converts the temperature signal into 4~20mA DC unified output signal which is in direct proportion with the thermocouple/thermal resistor temperature or the output electric signal, and then send it to display meter, recorder, adjusting meter or computer.
Flameproof, intrinsically safe thermocouple (resistance) temperature transmitter is designed and manufactured according to the " explosion-proof electrical equipment in explosive environment " (GB3836) standard regulated by the state, and the thermoelectricity performance is in line with international IEC standard, tested and approved by the national instrument explosion-proof safety Supervision Station, is an ideal integrated temperature transmitting product for explosive environment, and applicable for dangerous environment where there is flammable gas or liquid vapor.