Power Cable (CU/XLPE/PVC)

Power Cable (CU/XLPE/PVC)

Negotiable /Kilometer

Min.Order:1 Kilometer

Supply Ability:
4000 Kilometer / Kilometers per Month
Port:
qingdao/ningbo/shanghai
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
Henan, China
Brand Name:
HNTDDL
Insulation Material:
XLPE
Type:
Other, 0.6/1 kV 26/35kV
Application:
Underground
Conductor Material:
Copper

Henan Tong-Da Cable Co., Ltd.

Business Type: Manufacturer,Trading Company
Luoyang Henan China
Main Products: Conductor ,Cable ,Wire

Product Details

Specifications

26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.GB/T12706-2002 standard(The same as IEC60502).

Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE Sheathed Power Cable.


Executive Standard: 


It is manufacture under GB/T12706-2002 standard(The same as IEC60502). 


Application: 
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower.

 It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry

 and communication in complete replace of oil immersed paper insulated power cable and in partial replace

 of PVC insulated power cable. 


Using features: 


1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV. 


2. No. of core: Single-core, Three-core. 


3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250. 


4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997. 


5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated. 


6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter. 


7. Working Frequency Voltage Test:. 


For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. 
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture. 
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture. 


8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.

 

This series includes:

 

Copper (aluminum) core, XLPE insulated and sheathed power cables. 


Copper (aluminum) core, XLPE insulated, PE sheathed power cables. 


Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables. 


Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables. 


Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables. 


Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables 


Rated voltage: 0.6/1kV, 3.6/6kV. 


Number of cores: 1 to 6. 


Relative manufacturing standards: IEC60505, BS, DIN.

 

Packing: Wooden drum, steel wooden drum.

 

Power Cable 


-Conductor: 
Solid or stranded copper 


-Insulation: 
Cross-linked polyethylene( XLPE or PVC) 


-Circuit Identication: 
The insulation shall be red, black 


-Filler: 
Polypropylene lament with lapped binding tape 


-Inner Sheath: 
Polyvinyl chloride (Black) 


-Armor: 
Galvanized steel wire 


-Core-covering: 
Binding tape 


-Outer Sheath: 
Polyvinyl chloride (Black) 


-Application: 
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time. 


-Standards / Testing Specications: 
IEC 60502-1. 


Installation 


This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated 

by the Local Electric Code, or any equivalent, be followed,so that the safeguarding of persons and the integrity of the

 product will not be affected by eciencies in the installation. 


1. The products are mainly complying with IEC 60502 standard, also can be produced according to OEM 

requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc. 


Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor). 

Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more

 than 250 degrees. 


2. Brief Construction: 


Single core or multi-core 

Copper or aluminium conductor 

XLPE insulation 

Copper tape or copper wire screen 

Galvanized steel wire armored 

PVC or PE sheath

Contact Supplier

Mr. Admin hntddl Chat Now
Telephone
86-371-60311151
Fax
86-371-60311150
Address
No.299 Jinshui Road Pufa International Finance Center Mansion 1203 Room,Zhengzhou City Henan Province China Zhengzhou Branch Zhengzhou,Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories
Hi~