8.7/15KV Cable Al / XLPE /DSTA/ PVC cable

8.7/15KV Cable Al / XLPE /DSTA/ PVC cable

Negotiable /Kilometer

Min.Order:1 Kilometer

Supply Ability:
200 Kilometer / Kilometers per Month
Port:
NINGBO/SHANGHAI/QINGDAO
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
Henan, China
Brand Name:
HNTDDL
Insulation Material:
XLPE
Type:
Other, 8.7/15kV
Application:
Underground
Conductor Material:
Aluminum

Henan Tong-Da Cable Co., Ltd.

Business Type: Manufacturer,Trading Company
Luoyang Henan China
Main Products: Conductor ,Cable ,Wire

Product Details

Specifications

Al/CU Conductor XLPE/PVC Insulated Thin/Thick steel armored PE Sheathed Power Cable. AL/CU,XLPE/PVC,SWA/DSTA,PVC/PE

Relative manufacturing standards: IEC60505, BS, DIN,ASTM,JIS or other standards.


Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.


Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV and 0.6/1kV.
2. No. Of core: Single-core, Two-core,Three-core,Four-core,Five-core,Six-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250oC.
4. D. C. Resistance of the conductor complies with the stipulations of international standar.
5. The environment temperature should be no lower than zero degree when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of cables should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable

 

This series includes:

Copper (aluminum) conductor, XLPE/PVC insulated ,PVC sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, PE sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA) PVC sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA), PE sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PVC sheathed power Cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PE sheathed power cables

 

-Conductor:
Solid or stranded copper
-Insulation:
Cross-linked polyethylene/ polyvinyl chloride ( XLPE or PVC)
-Circuit Identication:
The insulation shall be red, black or other colors.
-Filler:
Polypropylene with lapped binding tape
-Inner Sheath:
Polyvinyl chloride (Black)
-Armor:
Galvanized steel wire or double steel tape armor
-Core-covering:
Binding tape
-Outer Sheath:
Polyvinyl chloride/ (Black)

 

Contact Supplier

Mr. Admin hntddl Chat Now
Telephone
86-371-60311151
Fax
86-371-60311150
Address
No.299 Jinshui Road Pufa International Finance Center Mansion 1203 Room,Zhengzhou City Henan Province China Zhengzhou Branch Zhengzhou,Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories
Hi~