Power AC/DC Clamp Meter Datalogger

Power AC/DC Clamp Meter Datalogger

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
3000 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Taiwan
Brand Name:
TES
Model Number:
TES-3063
Display Type:
Digital Only
Output Voltage:
600V
Operating Temperature:
0 °C to 50 °C

Shanghai Sunlight Electronic Technology Company Limited

Business Type: Trading Company
Shanghai China
Main Products: water quality meter ,environment meter ,optical instrument ,multimeter ,NDT meter

Product Details

Features:

RS-232 interface to talk with PC 
4 digits with dual display LCD 
Amp / Voltage f requency measurement 
Dual display KW+PF , KVA+PF , V+A 
4000 continuity point data logger , 25 point manual data logger 
True power / apparent power / power factor measurement 
True RMS. V , A , W , cap , lnd , phase indicator 
MIN / MAX measurement 
Peak hold detector 
Dual display A+Hz , V+Hz 
EN61010-1
600V Installation CAT III
Pollution Degree 2

Specifications:

True Power & Apparent power measurement

Input

Resolution

Accuracy

Frequency range

Overload protection

V<130V, A<150A

0.01

+/- (2%+5)

45Hz - 500Hz

600V/1100A

V>130V, A<150A

V<130V, A>150A

V>130V, A>150A

0.1

+/- (2%+1)

DCA

Range

Resolution

Accuracy

Overload protection

1000A

0.1A

+/- (1.5%rdg + 5dgts)

1100A

ACA

Range

Resolution

Accuracy

Frequency range

Overload protection

1000A

0.1A

+/- (1.5%rdg + 5dgts)

45Hz - 500Hz

1100A

 

Crest Factor: <4 for stated accuracy

DCV

Range

Resolution

Accuracy

Input Impedance

Overload protection

600V

0.1V

+/- (0.5%rdg + 5dgts)

 

1M Ω

600V

ACV

Range

Resolution

Accuracy

Input Impedance

Frequency range

Overload rotection

600V

0.1V

+/- (0.5%rdg + 5dgts)

1M Ω

45Hz - 500Hz

600Vms

Crest Factor: <3 for stated accuracy

Peak Indication

Range

Resolution

Accuracy

Overload protection

20A - 80A

0.1A

+/- (10%rdg + 10dgts)

1100A

80A - 1000A

+/- (6%rdg + 10dgts)

Peak Detect Acquisitions Time<=1ms

Peak Indication

Range

Resolution

Accuracy

Overload protection

20V - 80V

0.1V

+/- (10%rdg + 10dgts)

600Vrms

80V - 600V

+/- (6%rdg + 10dgts)

Peak Detect Acquisitions Time<=1ms

Audible continuity

Range

Continuity beeper

Open circuit voltage

Overload protection

<=0.050

<=3.2V

600Vrms

Resistance ( Ω )

Range

Resolution

Accuracy

Frequency range

Overload protection

10K Ω

1 Ω

+/- (1%rdg + 5dgts)

<=3.2V

600Vrms

Diode test

Range

Resolution

Overload protection

0.001V

600Vrms

Frequency (Hz)

Range

Resolution

Accuracy

Voltage sensitivity

Overload protection

1KHz

0.1Hz

+/- (0.5%rdg + 5dgts)

10V or 10A

600V / 1100A

5KHz

1Hz

Optional Accessories: TES-3064 RS-232 Interface Adaptor / Software

Genaral Specification

Maximum Voltage between any terminal and earth ground

600Vrms

Numerical Dual Display

4 digit liquid crystal display (LCD) maximum reding 9999.

Bargraph display

40 Segments.

Battery Life

30hr approx. (Alkaline)

Jaw Opening Diameter

Cables f 46mm.

Operating Temperature and Humidity

0 °Cto 50 °C (32 °F to 122 °F ) R.H. < 80% non-condensing.

Storage Temperature and Humidity

-10 °C to 60 °C (14 °F to 140 °F ) R.H. < 70% non-condensing.

Dimensions

260mm(L)* 93mm(W) * 45mm(H)

Weight

Approx. 450g

Accessories

Carrying Case, Test leads, One 9V Battery & Instruction manual

 

Contact Supplier

Mr. David Chen Sales Manager Chat Now
Telephone
86-21-51828967
Mobile
86 18621717855
Fax
86-21-51828367
Address
R.823 NO.1909 Caoan Road Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
Categories
Hi~