Power AC/DC Clamp Meter Datalogger
Negotiable /Piece
Min.Order:1 Piece
Shanghai Sunlight Electronic Technology Company Limited
Features:
RS-232 interface to talk with PC
4 digits with dual display LCD
Amp / Voltage f requency measurement
Dual display KW+PF , KVA+PF , V+A
4000 continuity point data logger , 25 point manual data logger
True power / apparent power / power factor measurement
True RMS. V , A , W , cap , lnd , phase indicator
MIN / MAX measurement
Peak hold detector
Dual display A+Hz , V+Hz
EN61010-1
600V Installation CAT III
Pollution Degree 2
Specifications:
True Power & Apparent power measurement
Input | Resolution | Accuracy | Frequency range | Overload protection |
V<130V, A<150A | 0.01 | +/- (2%+5) | 45Hz - 500Hz | 600V/1100A |
V>130V, A<150A | ||||
V<130V, A>150A | ||||
V>130V, A>150A | 0.1 | +/- (2%+1) |
DCA
Range | Resolution | Accuracy | Overload protection |
1000A | 0.1A | +/- (1.5%rdg + 5dgts) | 1100A |
ACA
Range | Resolution | Accuracy | Frequency range | Overload protection |
1000A | 0.1A | +/- (1.5%rdg + 5dgts) | 45Hz - 500Hz | 1100A |
Crest Factor: <4 for stated accuracy
DCV
Range | Resolution | Accuracy | Input Impedance | Overload protection |
600V | 0.1V | +/- (0.5%rdg + 5dgts) |
1M Ω | 600V |
ACV
Range | Resolution | Accuracy | Input Impedance | Frequency range | Overload rotection |
600V | 0.1V | +/- (0.5%rdg + 5dgts) | 1M Ω | 45Hz - 500Hz | 600Vms |
Crest Factor: <3 for stated accuracy
Peak Indication
Range | Resolution | Accuracy | Overload protection |
20A - 80A | 0.1A | +/- (10%rdg + 10dgts) | 1100A |
80A - 1000A | +/- (6%rdg + 10dgts) |
Peak Detect Acquisitions Time<=1ms
Peak Indication
Range | Resolution | Accuracy | Overload protection |
20V - 80V | 0.1V | +/- (10%rdg + 10dgts) | 600Vrms |
80V - 600V | +/- (6%rdg + 10dgts) |
Peak Detect Acquisitions Time<=1ms
Audible continuity
Range | Continuity beeper | Open circuit voltage | Overload protection |
<=0.050 | <=3.2V | 600Vrms |
Resistance ( Ω )
Range | Resolution | Accuracy | Frequency range | Overload protection |
10K Ω | 1 Ω | +/- (1%rdg + 5dgts) | <=3.2V | 600Vrms |
Diode test
Range | Resolution | Overload protection |
0.001V | 600Vrms |
Frequency (Hz)
Range | Resolution | Accuracy | Voltage sensitivity | Overload protection |
1KHz | 0.1Hz | +/- (0.5%rdg + 5dgts) | 10V or 10A | 600V / 1100A |
5KHz | 1Hz |
Optional Accessories: TES-3064 RS-232 Interface Adaptor / Software
Genaral Specification
Maximum Voltage between any terminal and earth ground | 600Vrms |
Numerical Dual Display | 4 digit liquid crystal display (LCD) maximum reding 9999. |
Bargraph display | 40 Segments. |
Battery Life | 30hr approx. (Alkaline) |
Jaw Opening Diameter | Cables f 46mm. |
Operating Temperature and Humidity | 0 °Cto 50 °C (32 °F to 122 °F ) R.H. < 80% non-condensing. |
Storage Temperature and Humidity | -10 °C to 60 °C (14 °F to 140 °F ) R.H. < 70% non-condensing. |
Dimensions | 260mm(L)* 93mm(W) * 45mm(H) |
Weight | Approx. 450g |
Accessories | Carrying Case, Test leads, One 9V Battery & Instruction manual |