New condition DGA gas chromatography transformer oil test machine,GC system
USD $1 - $10,000 /Set
Min.Order:1 Set
Chongqing TOP Oil Purifier Co., Ltd.
New condition DGA gas chromatography transformer oil test machine,GC system
Product Application
1. Applicable boiling range: petroleum products or distillates of 55~550℃ boiling range distribution such as fuel, kerosene, diesel, lubricants, wax oil etc. On this chromatographic condition tested sample components
can all show the peaks. It adopts area normalization method to fix quantity. It complies to SH/T 0558-2002 and ASTM D2887standard.
2. Applicable boiling range: crude oil of initial boiling point~538℃ boiling range distribution. Get distribution
proportion of fuel, diesel, kerosene, heavy oil. Since the heavy components above 538℃ can not show peak,
it adopts incremental internal standard method and complies to ASTM D5307 standard.
3. Applicable boiling range: petroleum products or distillates of 55~680℃ boiling range distribution. On this chromatographic condition tested sample components can all show the peaks. It adopts area normalization
method to fix quantity.
Product Features
1. Adopts American Agilent 5890 gas chromatographic core tech; green backlight LCD screen; easy operation.
2. Temperature control upper limit max use temperature of 450℃for every instrument heating area.
3. Dual channel single column compensation; base line drift when program heat to operate FID test;
ensure base line straight and chromatography peak shape perfect.
4. Adopts imported heat-resistant large aperture metal capillary column to separate; mas analysis
use temperature of 450℃.
5. Can display and print C5-C44 n-alkanes calibration sample boiling point-time calibration curve.
6. Can provide oil sample boiling point-yield boiling range curve.
7. Can provide detailed boiling range report regarding 1% yield interval; also can provide it regarding 5℃, 10℃, 20℃, 30℃, 50℃, 100℃ boiling range.
8. Can be equipped with AS-2902 highly efficient auto liquid sample injector; auto injection analysis with unattended operation achieved; analysis efficiency improved and labor intensity reduced.
Technical Parameter
Temperature control index
Oven/ Sample injector/ detector: above room temperature 5℃~450℃; precision ±0.1℃
Column oven parameters
Temperature control range: above room temperature 5℃~450℃; precision ±0.1℃
Program heating stages: 3 stages
Program heating speed: 0.1℃~50℃, increment 0.1℃
Program heating keeping time: 0~655 min (increment 1 min)
Big oven volume; back pullout design; program quick cooking after heating. Cooling speed: only 7min from 350℃ down to 60℃.
Injection method
Capillary split/unsplit stream injection: flash distillation injection
Packed column head injection: flash distillation injection
Can be equipped with unattended operation auto injector.
Hydrogen flame ionization detector (FID)
Easy disassembly and installation; convenient for cleaning and displacing nozzle; easy operation; can input signal to logarithmic amplification to reduce interference; high sensitivity, good linearity and wide range.
Limit of detection (LOD): Mt ≤ 5×10-12g/s (n-Hexadecath)
Baseline noise: ≤ 6×10-12A/H
Linearity range: ≥ 105
Stability time: < 0.5h
Chromatographic working station
24 bits high precision digital-to-analogue conversion (DAC)
Dual channel synchronous or asynchronous work
USB port; can be connected to external power supply; with serial port
Input voltage range: -1V~1V
Integral sensitivity: 0.05uV•s
Min solution: 1uV
Dynamic range (DR): 107
Sample frequency: Max 60 times/sec; adjustable program variables
N-alkanes analysis spectrogram
C5-C44 n-alkanes calibration sample boiling point-time calibration curve
Diesel simulated distillation spectrogram
You probably are looking for our flash point tester and mositure tester.
TOP mainly supplies products as follows:
Our oil purifying and recycling machines:
Series ZY Single-Stage Vacuum Transformer Oil Purifier
Series ZYD Double High Vacuum Transformer Oil Purifier
Series ZYB Multiply-Function insulating oil treatment machine
Series TY Turbine Oil Purification Apparatus
Series TYA Lubricating oil/ hydraulic oil purification unit
Series TYB Portable light Fuel oil purification machine
Series TYD Vacuum dehydrator
Series TYF Phosphate ester fire-resistance oil purifier
Series PL Plate pressure oil purifier
Series TYD Vacuum dehydrator
Series EFD Explosion protection filtration machine
Series BAM Press filtration system
Series ZKCC Vacuum pumping device
Series COP Cooking oil purification machine
Series CYS Centrifugal oil purification machine
Series JL Portable oil filtering and oiling machine
EOR series waste engine oil recycling system
Our major testers/ analyzers:
1.Transformer oil breakdown voltage tester ( BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer water content tester model TP-6A / model TP-2100
4. Moisture content tester(TPEE)
5. Fully automatic interfacial tension analyzer model IT-800
6. Gas-chromatography transformer oil gas analyzer model DGA2013-1
7. Consolidation point determinator model PT-2000
8. Kinematic viscosity tester model VST-2000
9. Flash point tester (open cup) model TPO-3000
10. Flash point tester (close cup) model TPC-3000
11. Transformer tester (CT/PT tester) model TPVA-404
12. Transformer turn ratio tester model HYG-II
13. Total base number analyzer(TBN tester) TBN-2030