Portable high accuracy argon gas analyzer/ easy operation gas tester with quick response
USD $1 - $2,000 /Set
Min.Order:1 Set
Chongqing TOP Oil Purifier Co., Ltd.
Chongqing TOP dissolved gas chromatograph,transformer oil dissolved gas analyzer
TP-3A LED Digital Display Moisture Analyzer, Water Content in Oil Tester
Insulating Oil Dielectric Loss,Tan Delta Testing Instruments,Power Factor Oil Tester
DGA series transformer oil gas chromatographic tester,GC system,ASTM D2887 and ASTM D5307
Introduction
Argon concentration analyzer AR-2500 is applicable for argon concentration detection in various industrial
environment and special environment. It adopts imported electrochemical sensor and micro-controller technique. It has quick response, high accuracy, good stability and repeatability and leading level performance.
Users can custom set up parameters with easy operation. It adopts high-capacity 4000mA NiMH
rechargeable battery of extra long standby; 3.5-inch high-resolution industrial color screen which perfectly
display technical indexes and gas concentration value; view historical data and curve chart. It owns many functions including printing data.
Feature
1. Adopts the latest ultra-low power consumption semiconductor nano-technology 32-bit microprocessor and
24-bit ADC data acquisition chip; owns the highest level measurement accuracy in this industry.
2. 3.5-inch industrial grade color screen with resolution of 320x480; automatically test the working status of
sensor, main chips and its components after power on.
3. Free switch among three concentration units of PPM,% VOL, mg / m3; automatic switch between high and low ranges; max detected concentration of 99.999% VOL.
4. Simultaneously detect 1~6 kinds of gases; freely optional sensors; simultaneously shows concentration of gases and alarm status on the screen.
5. With data storage function; can store 10000 group of data; can directly check historical data and curve graph on the screen.
6. Built-in powerful vacuum pump with pumping distance up to 5m; can work under the negative micropressure
environment; reasonable gas chamber design ensures the sensor free from pressure interference.
7. Besides detection of gas concentration, there are optional functions such as temperature / humidity sensor, microprinter, long-distance wireless transmission etc.
8. With functions of overvoltage protection, overcharge protection, short circuit protection, anti-static
interference, anti-magnetic interference etc.
Optional two kinds of detection modes of real-time detection and timing detection; timing detection can
measure the average value of the gas concentration within 30-3600 seconds.
With automatic recovery function to prevent breakage caused by any external or artificial factors etc.
9. Full software auto-calibration; sensor of up to six grade target point calibration; ensures testing accuracy
and has data recovery function.
10. Whole Chinese / English secondary operation menu; total standard 5-direction keys to operate on site;
additional 3 independent functional shortcut keys.
11. Full range temperature compensation function; with status indicators for power, pump, alarm, failure etc.
Technical parameter
Detected gas | Argon(Ar) | ||
Detection method | pump-sucking; built-in powerful vacuum pump; flow rate: 2 L/min, pumping distance 5-8m; can work under negative micro pressure environment. | ||
Detection range | 0-10%VOL | ||
Resolution | 0.01%VOL | ||
Detection accuracy | ≤±1%(the actual concentration, higher accuracy depends on the sensor) | Linearity error | ≤±1% |
Response time | ≤10s(T90) | Zero drift | ≤±1%(F.S/year) |
Recovery time | ≤10s | Repeatability | ≤±1% |
Explosion-proof mark | ExdII CT6 | Shell material | aluminum+sandblasting oxidation (scratch and corrosion resistant) |
Protection grade | IP65 | Working temperature | -30~60℃ |
Power supply | 4000mA rechargeable lithium battery | Working humidity | ≤95%RH; non-condensing |
Size&Weight | 120*190*190 mm; 2.0 Kg(instrument net weight) | Working pressure | -20Kpa — 100Kpa |
Standard configuration | Sampling handle×1 pc, 5*8mm hose×1 m, instrument case×1 pc, instruction manual×1 pc, certificate×1 pc | ||
Optional configuration | 1. micro printer: external; can be timed; automatic printing of each gas concentration data; portable. 2. temperature / humidity sensor: direct detection of gas temperature and humidity. 3. USB data cable×1 pc; data acquisition software×1 set 4. wireless transmitter: 1000-3000 m transmission distance; optional GPRS transmission for longer distance. |
Our oil purifying and recycling machines:
Series ZY Single-Stage Vacuum Transformer Oil Purifier
Series ZYD Double High Vacuum Transformer Oil Purifier
Series ZYB Multiply-Function insulating oil treatment machine
Series TY Turbine Oil Purification Apparatus
Series TYA Lubricating oil/ hydraulic oil purification unit
Series TYB Portable light Fuel oil purification machine
Series TYD Vacuum dehydrator
Series TYF Phosphate ester fire-resistance oil purifier
Series PL Plate pressure oil purifier
Series TYD Vacuum dehydrator
Series EFD Explosion protection filtration machine
Series BAM Press filtration system
Series ZKCC Vacuum pumping device
Series COP Cooking oil purification machine
Series CYS Centrifugal oil purification machine
Series JL Portable oil filtering and oiling machine
EOR series waste engine oil recycling system
Our major testers/ analyzers:
1.Transformer oil breakdown voltage tester ( BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer water content tester model TP-6A / model TP-2100
4. Moisture content tester(TPEE)
5. Fully automatic interfacial tension analyzer model IT-800
6. Gas-chromatography transformer oil gas analyzer model DGA2013-1
7. Consolidation point determinator model PT-2000
8. Kinematic viscosity tester model VST-2000
9. Flash point tester (open cup) model TPO-3000
10. Flash point tester (close cup) model TPC-3000
11. Transformer tester (CT/PT tester) model TPVA-404
12. Transformer turn ratio tester model HYG-II
13. Total base number analyzer(TBN tester) TBN-2030