220V 10KW Power Frequency Pure Sine Inverter for Electric Power
Negotiable /Set
Min.Order:10 Sets
Guangdong Kingwood Electronic Co., Ltd.
220V 7500W Power Frequency Pure Sine Inverter for Electric Power
220V 3000W Power Frequency Pure Sine Inverter for Electric Power
220V 2000W Power Frequency Pure Sine Inverter for Electric Power
48V 2000W Industrial Frequency Pure Sine Inverter for communications
48V 500W Industrial Frequency Pure Sine Inverter for communications
48V 6000W Power Frequency Pure Sine Inverter for communications
220V Power Frequency Pure Sine Inverter for Electric Power
Introduction:
KINGWOOD Pure Sine Wave Inverter / Power Inverter / Inverter Power Supply adopts the advanced SPWM and CUP control technology. With the strongpoints such as high reliability, perfect protection function, low waveform distortion and lower price etc.The inverter has high invert efficiency (in the condition of full load, the invert efficiency can be up to 85%). At the same time, this inverter have strong non liner load driving capability. Also, Inverter can control the monitor the input voltage/current, output voltage/current. Inverter can realize the function of unattended operation.
D Series 220V Pure Sine Wave Inverter / Power Inverter / Inverter Power Supply is mainly used in power plant, electric power system, railway and other places.
Features:
Technical Parameters:
Technical Index | DA-7.5KD | DA-10KD | ||
DC Input | Rated Voltage | 220 Vdc | ||
Rated Current | 32 A | 53.5 A | ||
Voltage Range | 180 — 280 Vdc | |||
Current without load | 0.8 A | 1.0 A | ||
Ripple Noise | ≤3% | |||
Ripple Noise Reverse | ≤1% | |||
AC Output | Rated Cpacity | 7.5 KVA | 10 KVA | |
Rated Power | 6 KW | 8 KW | ||
Rated Voltage and Frequency | 220Vac, 50Hz | |||
Rated Current | 27.0 A | 36.5 A | ||
Voltage Accuracy | 220 V±3% | |||
Frequency Accuracy | 50 Hz±0.5% | |||
Waveform Distortion (THD) (linear load) | ≤3% | |||
Dynamic Response (load 0~100%) | 5% | |||
Power Factor (PF) | 0.8 | |||
Overload Ability | 150% 10s | |||
Inver Efficiency (80% resistive load) | ≥90% | |||
Bypass conversion time | ≤10 ms | |||
Environment | Insulation Strength Vac (input-output, input-shell, output-shell) | 1500 | ||
Noise (1 m) | ≤45dB | |||
Operation Temperature | 0 — +40°C | |||
Humidity | ≤90% (20°C±5°C) | |||
Altitude | ≤1000 m | |||
Dimention | D×W×H (mm) | 450×600×1200 | ||
Weight | 120 kg | 150 kg | ||
Protection | Output Overload | Close after 10s when the load power is more than 150% | Restart to recover | |
Output Short-circuit | Device will close automatically | |||
Input Reverse | Device will close automatically | The output will recover automatically after the input voltage is normal. | ||
Input Undervoltage | Dc<180±5V, device will close automatically | |||
Input Overvoltage | Dc>280±5V, device will close automatically | |||