pure sine circuit 3kw price 6kw ac stepper micro dc motor 2000w inverter
USD $165 - $166 /Box
Min.Order:1 Box
pure sine wave air star spare parts 300w tronic power inverter
spare parts 300w tronic power in dubai china elevator door inverter
pure sine wave dc to ac 10000 watt 3000 watts 2000w power inverter
mig mag pure sine circuit 3kw car zx7-315 dc arc welder inverter
dc air conditioner 1000w circuit generator goodwe german 10000w inverter
esab welding machine best lcd heat pump siei art drive l inverter
High frequency vector inverter
Control Characteristics
Control mode | Sine wave PWM mode selectable by parameter setting four control modes (2) V / F control attached PG feedback (3) Current speed sensorless flux vector control (4) flux vector current control PG feedback | |
Starting torque | 150% / zero rpm (when not accompanied by PG 150% / 1Hz) | |
Speed control range | 1: 1000 (when the PG is not attached 1: 100) | |
Speed control accuracy | ± 0.02% (when not attached PG ± 0.2%) | |
Speed response | 30Hz (33ms) (PG when not attached 5Hz (200ms)) | |
Torque limit | By parameter settings can be independently set four quadrants | |
Torque Control | Four-quadrant operation possible (Forward Motor / regenerative reversal electric / resuscitation) | |
Torque response | 40Hz (25ms) (PG when not attached 20Hz (50ms)) | |
Frequency control range | 0.01~1300Hz | |
Frequency control accuracy | Digital signal: ± 0.01% (-10 ℃ ~ + 40 ℃) analog signal: ± 0.1% (25 ℃ ± 10 ℃) | |
Frequency setting resolution | Digital signal: 0.01Hz Analog signals: 0.03Hz / 60Hz * (12bit) | |
Frequency output resolution | 0.01Hz | |
overload | 150% of rated current 1 minute PER10MIN @ 40 ℃ above | |
Analog frequency setting signal | DC-10~+10V,0~10V(20KΩ)4 ~ 20mA(250Ω) | |
Acceleration and deceleration time | 0.01 to 6000.0 seconds (four groups of acceleration, deceleration time set individually) | |
Brake torque | Approximately 20% additional Brake up to 150% | |
Run / stop setting | Operator, RS232, RS485 / 422, the control circuit terminals, 12/16 BiT binary signal | |
Protective function | ||
Motor protection | Electronic thermal relay protection, under phase protection | |
Instantaneous overcurrent | 200% of the rated current of the motor free stop | |
Fuse protection | Motor stops after the fuse blows freely | |
Overload | Motor freedom stops at more than 150% of the rated output current of about 1 minute PER10MIN @ 40 ℃ | |
Overvoltage | Main circuit DC voltage of about 220V class 400V, 440V 800V class about free stop over motor | |
Low Voltage | Main circuit DC voltage of about 220V class 200V, 440V 400V class about freedom following motor stop | |
Instantaneous power compensation | After the operation mode selection within 2Sec blackouts continue to operate (external capacitor) | |
Fin overheat | Thermocouple Protection | |
Stall prevention | Acceleration and deceleration, stall prevention operation | |
Ground protection | Electronic circuit protection | |
Charging indicator | he main circuit DC voltage above 50V charging indicator "light" | |
Vibration | 20Hz below 1G, 20 ~ 50Hz when 0.2G | |
Efficiency | Pf>0.95&η>0.95@40℃ abov |
[SIZE]