Remote Control SMS Digital Temperature and Humidity Controller
USD $300 - $500 /Set
Min.Order:1 Set
Guangzhou Richcomm System Technologies Co., Ltd.
Mobilemate
Overview
With an elegant and compact design, Mobilemate SMS monitor has been widely applied to the suburbs small data centers, unattended stations, which provides UPS monitoring and environment monitoring parameters query and alarm by SMS and network method.
Function
l Support advanced encrypted protocol such as HTTPS, SSL, SSH, SNMP Verion V1/V2c/V3;
l Support IPV4/IPV6 network protocol.
l Provide single/three phase UPS monitoring; support remotely control UPS of self-testing, shutdown, reboot , task schedule(need UPS support);
l Support to add on 2 Temp&Humid sensors via RS422;
l Support second add on dry contact type sensors via Temp&Humid sensor;
l Support E-mail, SNMP trap alarm notification;
l Support SMS query and alarm notification;
l Multi-user authority management;
l Support history event and history data record;
l With time synchronization function;
l Available to work with centralized software.
Ports Introduction
Dimension
Network Diagram
Technical Parameters
CPU | 32-bit ARM RISC-based 50 MHz CPU |
RAM | 64M byte SDRAM |
Flash ROM | 128M byte Flash |
Network Port | 10/100Mbps high-speed Ethernet self-adaptive |
Serial Port | 1 RS232 Port( To connect UPS/Precision Air Conditioning) |
1 RS422Port(To connect Temp &humid sensor and air condition infrared control) | |
Browser Support | Support Internet Explorer, Netscape or other compatible browser |
SNMP MIB | MIB-II(RFC1213, RFC1315, RFC1316), PPC MIB, RFC1628 MIB |
Network Protocol | TCP/IP, UDP, SNMP, Telnet, SNTP, HTTP, SMTP, DHCP, DNS, TFTP, ARP, ICMP, PPP, etc. |
LED Indicator | Power, Status, Ready, LAN 10/100M Link/Active |
Input Power (DC) | 8 ~ 15V |
Power Consumption | ≤5W |
Running Environment | Temperature: 0°C ~ 70°C |
Humidity: 10 ~ 85% | |
Other Configuration | Real-time system clock |
Multiple Languages | Chinese/English, support OEM to other languages |
Firmate Update | Network |
System Security | Provide IP based filtering mechanism, system operation, user ID control & management and password protection. |
Safety Certificate | ISO9000, ISO14001, CE, FCC |
Opitional Accessories
Picture | Name | Function | Specification |
|
Temp & Humid Sensor | OLCD Display | (Every 20 M² need to install 1pc of Temp & Humid Sensor) Environment Temperature Detection Range: -22 ℃ ~ +55 ℃. Accuracy: ±0.5 ℃. Environment Humidity Detection Range: 10% ~ 99%. Accuracy:± 3 %. Communication Mode: Full-duplex RS-485. |
Digital Type | |||
| Smoke Sensor | Smoke Fire Status Detect | (Every 20 M²-30M² need to install 1pc of Smoke Sensor) Sensor: Ionic. Operating Voltage: DC12V/24V. Working Current: ESD Current<10ua Alarm Working Current10-20ma. Working Environment:-5℃~50℃. Alarm Output:Live alarm signal output connect monitor host, alarm eliminate auto disconnect Dimention: Φ107mm*50mm |
| Infrared Detector | Intrusion Detection | Working Voltage: DC 9~16V. Current Loss: 12vmA. Horizontal: ±25º. Vertical: +5º~-20º. |
| Door Contact Sensor | Door/Windows On-Off Status Detection | Operational Power Supply:12V . Operating Current:<15mA. Static Current:3mA. Operating Frequency: 315MHz. Frequency Deviation: ±0.2MHz. Transmitting Power: >15mw. Transmitting Distance: >100m(open) Transmitting Time: 1.5S-3S Effient Range:closed:-15mm, open-3 |
| Switching Value Transmitter | Air Conditioning/ New Fan On-Off Status Detetcion | Power Frequency Withstand Voltage: 1.0kV/1min1mA. Insulation Resistance: >100MΩ. Power Influence: DC24V +/- 15%. Inspection Temperature: 23°C. Inspection Humidity: 60%RH. |
| Non-Location Water Leakage Collector | Leakage Detection | Sensitivity: 2mm-100mm adjustable (water supply). Response Time: <1s. Power Requirement: 12VDC polarity connection . Relay Output: 1SPDT,60VDC or 125VAC,1A rated value (constant on/off). |
Non-Location Water Leakage Cable(5/10/15/20/30M) | |||
| Air Conditioning Smart Controller | Remote Control Air Conditioning on-off, with auto reboot when AC recover | Input Power 5V-15VDV, Rated Power12VDC Average Power Consumption:<20mA Temperature Range:-10℃~-50℃ Humodity Range:10%~90%RH Output: An (OFF/ON) to control signal. |
Typical Application
Non Network/Serious Network Condition,
UPS Monitoring,
Server Room Monitoring,
Data Center Monitoring,
Environmental, Monitoring,
Networking Monitoring,
IT Solution,
IT Service, etc.