(D5 Series) Closed Loop Mode Mini Hall Effect Current Sensor
USD $1 - $20 /Piece
Min.Order:10 Pieces
Jiangyin Spark Electronic Technology Co., Ltd.
Closed Loop Mode Hall Effect Current Sensor for Battery Supplied Applications
(C5N Series) Class 0.5 Open Loop Mode Hall Effect Current Sensor with UL94-V0
(A-C2T Series) Open Loop Dismountable Hall Effect Current Sensor with CE
(D-C3T) Split Core Hall Effect Sensor Miniature Clamp on DC Current Sensor
Clip on Hall Effect Current Sensor (D-C2T) Current Transducer Mini Hall Switch Sensor
Hall effect current sensor
The D5 Series current sensor is a closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit, the size of primary doesn't affect test precision, no matter the location of primary in the hole of current sensor. It can really measure resolution 1000:1, it uses for precision measurement of DC, AC and pulse current.
Electrical data (Ta=25ºC±5ºC) |
Type | D5-50A | D5-100A | D5-200A | D5-300A | Unit |
Rated current(Ipn) | ±50 | ±100 | ±200 | ±300 | A |
Measure range(Ip) | 0-±75 | 0-±150 | 0-±300 | 0-±450 | A |
Turns ratio(Np/Ns) | 1:1000 | 1:2000 | 1:2000 | 1:2000 | T |
Measure resister with±15V | @±50Amax 0(min)186(max) | @±100Amax 0(min)175(max) | @±200Amax 0(min)100(max) | @±300Amax 0(min)56(max) | Ω |
@±75Amax 0(min)117(max) | @±150Amax 0(min)106(max) | @±300Amax 0(min)56(max) | @±450Amax 0(min)21(max) | Ω | |
Measure resister with±18V | @±50Amax 0(min)304(max) | @±100Amax 0(min)293(max) | @±200Amax 0(min)130(max) | @±300Amax 0(min)75(max) | Ω |
@±75Amax 0(min)159(max) | @±150Amax 0(min)148(max) | @±300Amax 0(min)75(max) | @±450Amax 0(min)31(max) | Ω | |
Coil resister | 14 | 25 | 25 | 25 | Ω |
Rated output | 50 | 50 | 100 | 150 | mA |
Supply voltage | ±12,±15,±18 | V | |||
Power Consumption | ≤20+IpX(Np/Ns) | mA | |||
Offset current | @Ip=0 ±0.2 | mA | |||
Offset drift | @ -40~+85ºC ≤±0.5 | mA | |||
Linearity | @Ip=0-±Ipn ≤0.1 | %FS | |||
Response time | @50A/μS, 10%-90% ≤1 | μS | |||
Galvanic isolation | @ 50HZ,AC,1min 6 | KV | |||
di/dt | >100 | A/us | |||
Bandwidth | @ -1dB 0~150 | KHZ |
Applications |
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:I0UT 4:NC
Directions for use |
1. When the current will be measured goes through a sensor, the current will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output current are available.
Standards |
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
General date |
Value | Unit | |
Operating temperature(TA) | -40 to +85 | ºC |
Storage temperature(TS) | -40 to +125 | ºC |
Mass(approx) (M) | 79 | g |