MOS-620,20MHz low cost oscilloscope

MOS-620,20MHz low cost oscilloscope

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
5000 Piece / Pieces per Month
Port:
xiamen shenzhen
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Fujian, China
Brand Name:
OEM
Model Number:
MOS-620

Xiamen Wellzion Electronics Co., Ltd.

Business Type: Trading Company
Xiamen Fujian China
Main Products: Power Supply ,Oscilloscope ,Multimeter ,Spectrum Analyzer ,Temperature Test Instruments

Product Details

MOS-620,20MHz low cost oscilloscope

Features and Benefits:

 Specifications 

X-Y MODE
Frequency bandwidthDC to at least 500KHz
X-Y phase difference3°at DC~50KHz
SensitivitySame as vertical axis. (X-axis:CH1 input signal; Y-axis:CH2 input signal.)
ZAXIS
Sensitivity5Vp-p (Positive-going signal decreases intensity)
Frequency bandwidthDC~2MHz
Input resistanceApprox.47KΩ
Maximum input voltage30V (DC+AC peak, AC frequency1KHz)
CALIBRATION SIGNAL
WaveformPositive-going square wave
FrequencyApprox. 1KHz
Duty ratioWithin 48:52
Output voltage2Vp-p±2%
Output impedanceApprox.1KΩ
CRT
Type6-inch rectangular type, internal graticule
PhosphorP31
Acceleration voltageApprox.2KV(20MHz)/Approx.12kv(40MHz)
Effective screen size8×10DIV[1DIV=10mm(0.39in)]
GraticuleInternal
Trace rotationProvided
VERTICAL AXIS
Sensitivity accuracy3%(x5 MAG:5%)
DC balance shift5mV~5V/DIV: ±0.5DIV, 1mV~2mV/DIV ±2.0DIV
BandwidthDC~20MHz(x5MAG:DC~7MHz)
Linearity<±0.1DIV of amplitude change when waveform of 2DIV at graticule center is moved vertically
Vernier vertical sensitivitycontinously variable to 1/2.5 or less of panel-indicated value
Rise timeApprox.17.5ns (x5 MAG: Approx.50nS)
Input impedanceApprox.1MΩ/Approx.25pF
Sensitivity5mV~5V/DIV,10 steps in 1-2-5sequence
AC couplingLow limit frequency 10Hz.(With reference to 100KHz, 8DIV, Frequency response with-3dB.)
Vertical modesCH1,CH2,DUAL,ADD
Chopping repetition frequencyApprox. 250KHz
Input couplingAC, GND, DC
Maximum input voltage300Vpeak (AC: frequency 1KHz or lower)
Common mode rejection ratio50:1 or better at 50KHz sinusoidal wave.(When sensitivities of Ch1 and Ch2 are set equally)
Isolation between channels (At 5mV/DIV range)>1000:1 at 50KHz;
>30:1 at 15MHz/>30:1 at 35MHz/>30:1 at 45MHz
CH1 signal outputAt least 20mV/DIV into a 50Ω termination. Bandwidth is 50Hz to at least 5MHz
CH2 INV BALBalanced point variation:1DIV (Reference at center graticule)
TRIGGERING
Triggering  sourceCH1,CH2,LINE,EXT
CouplingAC: 20Hz to full bandwidth
SLOPE+/-
Sensitivity20Hz~2MHz:0.5DIV, TRIG-ALT:2DIV EXT:200mV;RIG-ALT:3DIV,EXT:800mV
2~20MHz:1.5DIV;20MHz~40MHz:2.5DIV;40MHz~50MHz:3DIV
TV: Sync pulse more than 1 DIV (EXT:1V)
Triggering modesAUTO; NORM: TV-V: TV-H: (Both TV-V and TV-H synchronize only when the synchronizing signal is negative)
EXT triggering signal inputInput impedance/: Approx:1MΩ/approx.25pF
Max.input voltage
 
300V (DC+AC peak), AC: Frequency not higher than 1KH

 

Contact Supplier

Ms. Melissa Zhang Chat Now
Telephone
86-592-5562446
Fax
86-592-5562446
Address
ROOM 608,B BUILDING,SEG E-MART, NO.806 YUANSHAN NAN ROAD,XIAMEN,FUJIAN,CHINA Xiamen,Fujian

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electronic Measuring Instruments > Oscilloscopes
Categories
Hi~