Toxic Gas Transmitter
USD $500 - $1,000 /Unit
Min.Order:1 Unit
AMBETRONICS ENGINEERS PRIVATE LIMITED
Toxic Gas Transmitter
FEATURES:
APPLICATIONS:
TECHNICAL SPECIFICATION | ||
Input | Oxygen / Toxic / Combustible Gases, Please select from the Table | |
Range / Resolution | As specified in the Table | |
Accuracy | ± 1% of the full scale value | |
Sensor type | Electrochemical / Catalytic Pellister / Solid State / Infra Red based Sensors | |
Standard output | Programmable Linear 4-20 / 20-4 mA O/P with respect to Gas concentration range | |
Dual Display | 1) Upper :- 4 Digit of 13mm(H) Red LED display for 'Gas Concentration' indication 2) Lower :- 4 Digit of 13mm(H) Red LED display for 'Set Point Value’ of Alarm Relay-1/ Unit of Gas | |
LED Indication | AL1 & AL2 for Relay, FLT for Fail-Safe Relay, PRG for Programming mode, INB for Service / Inhibit mode, TST for Test mode, TX for Transmitting signal, RX for Receiving signal. | |
Set point | 2 No, Independent set point. For Alarm Relay-1 & Alarm Relay-2 with programmable latch & non-latch facility | |
Control action | LO / HI, HI / LO, LO/ Very LO, HI-Very HI, Programmable by user | |
Hysteresis | 0 to 100 counts, Individual setting for Alarm Relay-1 & Alarm Relay-2, programmable by user | |
Setting | Setting by 4 keys on front panel i.e. 'SET / NEXT', 'UP', 'DOWN' & 'TEST / BACK' | |
Monitoring | 1)By display : Sensor break/ open shows 'oPEn', under range shows 'Undr' & over range shows 'ouEr' 2)By Standard O/P current : Upscale current : 21mA, Down scale current : 3mA, selectable | |
Supply Voltage | 18 to 36 VDC | |
Cable | 1.5 sq. mm 3 Core, Flexible OR Armored shielded cable | |
Operating Temperature | 0 to 500C ± 5%, Relative Humidity: Below 95% non condensing | |
Sensor Housing | P.V.C. / P.P. / TEFLON material / SS304/SS316, Please select while ordering | |
Enclosure Detail | GT - 2000 - WP (Weatherproof ) | GT - 2000 - FLP(Flameproof ) |
Protection Class | IP-65 | IP-65 for Gas Gr. IIA & IIB, ATEX,CCOE & CMRI Approved |
Cabinet Material | Polycarbonate, gray colour | Cast Aluminium alloy, LM-6 / C.I. Enclosure |
Cable Entry | Thermoplastic cable gland (IP 68) with clamping range of 2.5 to 6.5mm | Double compression cable gland (Ex-Proof), 3/4" ET type |
Dimension | 255 mm (H) x 240 mm (W) x 120 mm (D) | 180 mm (H) x 205 mm (W) x 110 mm (D) |
Mounting | Wall Mounting / Stand Mounting | Wall Mounting / Stand Mounting |
Weight | Approx 2.0 Kg | Approx 3.0 Kg |
Optional | a) Isolated RS-485 Serial port with MODBUS RTU protocol output b) SMARTLOG / SCADA SOFTWARE for online graph & data report for safety Audit c) Flame Proof or Non Flame Proof Industrial Hooter, Hooter cum Flasher, Chart recorder, Cables, PC Software, Gas Transmitters, 24 VDC power supply, Gas calibration kit d) Optional 3 No, 1 NO-C-NC, 230 VAC/5A Potential Free Relay contacts for AL-l, AL-2, & Fail Safe Relay |