Data logger
Negotiable /Unit
Min.Order:1 Unit
AMBETRONICS ENGINEERS PRIVATE LIMITED
voltage data logger
FEATURES:
APPLICATIONS:
TECHNICAL SPECIFICATIONS: | ||||
Inputs | Range | Resolution | Accuracy | |
Minimum | Maximum | Normal | Full Scale | |
RTD PT 100 (3 WIRE) | -200°C | 400.0°C | 0.1 | ±0.25% |
J Type (Fe - CON) | -50.0°C | 600.0°C | 0.1 | ±0.25% |
K Type (Cr- AL) | -50.0°C | 500.0°C | 0.1 | ±0.25% |
K Type (Cr- AL), N Type | -50°C | 1300°C | 1 | ±0.25% |
R Type (PT 13 % RH / PT), S TYPE (PT 13 % RH / PT) | 0°C | 1750°C | 1 | ±0.25% |
T Type (Cu / CON) | -200°C | 400.0°C | 0.1 | ±0.25% |
E Type (NI Cr / CON) | 0°C | 1000°C | 1 | ±0.25% |
B Type (PT 6 % RH / PT 30 %RH) | 400°C | 1820°C | 1 | ±0.25% |
4~20 Ma / 0 ~20 mA | -999 | 9999 | Programmable by User | ±0.25% |
Voltage (0 ~1 VDC / 0~ 10 VDC) | -999 | 9999 | ±0.25% |
Display | 4 digits of 13 mm Height Red L.E.D display for 'Process Value' indication 1 digit of 13 mm Height Red L.E.D display for 'Channel Number' indication | ||
L.E.D. Indication | 8 Nos Red L.E.Ds of 3 mm for Alarm Indications i.e.AL1 & AL 2 | ||
Set Point | 2 independent set points for each channel with 2 common relay outputs & programmable latch / non-latch facility for 2 common relays & Alarm indications | ||
Control action | HI - LO, LO - Very LO, HI-Very HI; programmable by user | ||
Relay Output | 1 NO/C/NC Relay Contact Rated 230VAC/5A for Relay-1 (AL1) & Relay-2 (AL2) | ||
Setting | Setting by 5 feather touch keypad on front panel 'MODE', SHIFT','INC', 'ENT', PRN /ACK' | ||
Scan Time | 1 to 59 sec scan/scroll time between each channel; programmable by user | ||
Print Interval (Optional) | 5 to 9999 Sec for Direct print out on 24 / 80 / 132 Column Dot matrix Printer | ||
Logging Interval | 1 to 9999 Sec login interval in data logger model; programmable by user | ||
Memory | Max. 5000 readings storing capacity for all 8 channel in Data Logger model Memory saturation, Memory Scrolling (FIFO) & Online PC Interface available in Data Logger model | ||
Monitoring: Sensor | Temperature sensor Break / Open display shows 'oPEn' indication | ||
Open / Under / Over | Under range 'undr'. Over range 'OuEr' indication for RTD & all Thermocouple I/Ps | ||
Supply Voltage | 230 VAC ±10%, OR 110 VAC±10% OR 24 VDC OR 12 VDC | ||
Operating Temperature | - 40 To 85° C Relative Humidity : Below 95% non condensing | ||
Enclosure Details | Panel Mount | Weatherproof | Flameproof |
Protection Class | IP-40 | IP-65 | IP-65, CMRI for IIA & IIB Gas Group |
Cabinet Material | ABS Plastic, White Colour | Polycarbonate, gray colour | Cast Aluminum alloy, LM-6 / C.I. Enclosure |
Cable Entry | Terminal Connector for Connection | Thermoplastic cable gland (IP 68) | Double compression cable gland, ¾ ET-type |