Flame Proof process controller
Negotiable /Unit
Min.Order:1 Unit
AMBETRONICS ENGINEERS PRIVATE LIMITED
Flame Proof process controller
FEATURES:
APPLICATIONS:
TECHNICAL SPECIFICATIONS: | |||
Input | 2 No X Humidity or Temp or Pressure or Any Process Transmitter having 4 - 20mA Output | ||
Range | -999 To 9999; programmable by user | ||
Resolution | 0.001, 0.01, 0.1, 1; programmable by user | ||
Accuracy | ± 0.25% of Full Scale | ||
Display | Upper : CH-1, 4 Digit, 0.56inch (13 mm), 7 segment RED L.E.D display Lower : CH-2, 4 Digit, 0.56inch (13 mm), 7 segment RED L.E.D display | ||
L.E.D. Indication | TD1 & TD2 for Time Delay, RL1 & RL2 for Relays, TX & RX for Communication, PRG to show user in programming Mode & SQR to show 'Process Value'on both CH-1 & CH-2 is square root of the I/Ps | ||
Set point | Two Independent set points, one each for RL1 & RL2 with programmable Latch / Non - Latch facility | ||
Hysteresis | 0 To 10, Individual setting for RL1 & RL2 | ||
Control action | LO -HI, HI-LO, LO- Very LO, HI - Very HI; programmable by user | ||
Time delay | 0 To 9999 sec, Independent setting for RL1 & RL2 to operate after the 'Process Value'crosses the 'Set point Value' | ||
Relay contact type | 1 NO - C - NC Relay Contact Rated 230 VAC/5A for RL1 & RL2 | ||
Configuration of relay | RL1 operates for CH-1, RL2 operates for CH-2 | ||
Fault condition | In 'Under', 'Over'OR 'Open' condition i.e. fault condition, Relay can be made OFF or ON; programmable by user | ||
Setting | Setting by 4 keys on front panel i.e. 'SET / NEXT', 'UP', 'DOWN' & 'BACK' | ||
Monitoring : Sensor Open / Under / Over | i) By Display : Sensor 'Break/ Open'shows 'oPEn', 'Under' range shows 'Undr' & 'Over' range shows 'ouEr' ii) By Retransmission current O/P : Upscale current : 21 mA, Down scale current : 3 mA; programmable by user | ||
Retransmission output (Optional) | I) 2 No, 4 - 20 mA or 20 - 4 mA programmable with MAX load 750 ohms for CH - 1 & CH - 2 ii) Range: - 999 To 9999, Low range / High range: Anywhere in the range (High range > Low range) | ||
Communication | Modbus RTU Protocol with Isolated RS-485 Communication | ||
Supply Voltage | 230 VAC ± 10% OR 110 VAC ± 10% OR 24 VDC | ||
Operating Temp. | - 40 To 85°C | ||
Relative Humidity | Below 95% non condensing | ||
Enclosure Detail | PANEL MOUNTING (PM) | WEATHERPROOF (WP) | FLAMEPROOF (FLP) |
Protection Class | IP - 40 | IP- 65 | IP-65, CMRI for IIA & IIB Gas group |
Cabinet Material | ABS Plastic, White Colour | Polycarbonate, Grey colour | Cast Alluminium alloy, LM-6 / C.I. Enclosure |
Cable Entry | Terminal connector for connection | Thermoplastic cable gland (IP - 68) | Double compression cable gland (Ex-Proof),¾inch ET-type |
Dimension | 96 (H) X 96 (W) X 120 (D) in mm | 215 (H) X 240 (W) X 120 (D) in mm | 300 (H) X 250 (W) X 110 (D) in mm |
Cutout | 92 (H) X 92 (W) in mm | - - - - | - - - - |
Mounting | Panel mounting | Wall Mounting / Stand Mounting | Wall Mounting / Stand Mounting |
Weight | Approx. 1.0 Kg | Approx. 2.5 Kg | Approx. 4.0 Kg |