POCT for specific protein analyser/HbA1c Analyzer/Immunoassay System
USD $100 - $1,500 /Set
Min.Order:1 Set
Hunan Lituo Biotechnology Co., Ltd.
Features & Properties.
Test principle: Immuno Scatter turbidmetry . Higher accuracy and broader linearity.
Test items: Accurate and fast assay for CRP, HS-CRP, HbA1c, Urine Microalbumin, IgA, IgG, IgM, C3, C4 and β2- MG.
Test channel: Four channels can run 4 different tests simultaneously.
Sample types: Whole blood, Serum and Urine etc.
Calibration: Built-in magnetic card. No need to do calibration curve.
Detection speed: 120 Tests/Hour
Result Storage: LIS (Laboratory Information System) connectivity through RS232 port. 1000 results storage for each channel.
Traceability: Calibration with the International Reference Material CRM470.
LTS-T1000 provides accurate and fast assay for CRP (CRP and HS-CRP), HbA1c, Urine Microalbumin, IgA, IgG, IgM, C3, C4 and β2- MG.
LTS-T1000 provides accurate and fast assay for CRP (CRP and HS-CRP), HbA1c, Urine Microalbumin, IgA, IgG, IgM, C3, C4 and β2- MG.
Test items | Measurement rages | Sample type | Clinical significance |
CRP |
0.5-210mg/L |
Whole blood | C– reactive protein (CRP) is an acute phase protein produced by the liver in response to inflammation, infection and tissue injury. CRP is useful for both the detection of acute episodes as well as in treatment monitoring. |
HbA1c |
3%-15% |
Whole blood | The concentration of HbA1c in the blood of diabetic patients increases with rising blood glucose levels and is representative of the mean blood glucose level over the preceding six to eight weeks. HbA1c can therefore be described as a long term indicator of diabetic control. |
Urine Microalbumin |
10-200 mg/L |
Urine | When the kidneys are damaged, small amounts of albumin leak into the urine. Microalbuminuria is most frequently caused by kidney damage from diabetes. When the kidneys spill protein, it can mean serious kidney damage is present. This can lead to chronic kidney disease. |
IgA |
0.25-5.0g/L |
Serum | Measurement of IgA is used to diagnose diseases of the respiratory tract e.g. tuberculosis, Crohn’s disease and early cirrhosis of the liver. It is also useful in monitoring therapy of IgA myeloma and evaluating IgA immunity. |
IgG |
2-25g/L |
Serum | Measurement of immunoglobulin G is the basis of the serological diagnosis of several infectious diseases. Uses of IgG measurement include diagnosis of infectious and inflammatory diseases, diagnosis of malignancies, to detect the presence of soluble antigens and monitoring therapy in myeloma. |
IgM |
0.25-4g/L |
Serum | IgM measurement has the following uses: to establish diagnosis and monitor therapy in Waldenström’s macroglobulinemia and plasma cell myeloma, to detect intra-uterine infection by measuring levels in new born babies, diagnosis of primary biliary cirrhosis, viral hepatitis, rheumatoid arthritis and parasitic infections. |
C3 | 0.24-4.5g/L | Serum | Complement is a complex biological system which works in conjunction with antibodies and other factors to protect the body from invasion by pathogens. When activated by either the classical or alternative pathway Complement acts on biological membranes and may cause cell death. Complement C3 and Complement C4 levels are important in determining inherited or acquired deficiencies. |
C4 | 0.07-2.0G/L | Serum | |
β2- MG | 0.5-12mg/L for Serum 1.0-20mg/L for Whole Blood | Serum, Whole blood | Beta-2-Microglobulin is a low molecular weight protein found on the surface of most cells, including white blood cells. When kidney disease is suspected, comparing blood and urine levels helps identify where the kidney is damaged. |
Initiated from 2000, Lituo Biotech is a national hi-tech enterprise specializing in R&D, production and marketing of high-quality in-vitro diagnostic reagents and clinical laboratory instruments.
Lituo Biotech has strong R&D capability and leads the industry tendency. Lituo developed nearly 30 products including diagnostic reagents and instruments benefiting from its high calibre R&D teams, high investment of scientific research and efficient R&D management system.