two/three-zone Heat Shock Test Chamber thermal shock testing
two/three-zone Heat Shock Test Chamber thermal shock testing

two/three-zone Heat Shock Test Chamber thermal shock testing

USD $15,000 - $50,000 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
shenzhen
Payment Terms:
T/T L/C D/P D/A

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
KOMEG
Model Number:
TST-A Series
Power:
Electronic
Usage:
Process Testing Machine

Guangdong KOMEG Technology Ind Co., Limited

Business Type: Manufacturer,Trading Company
Dongguan Guangdong China
Main Products: Temperature & Humidity Test Chamber ,Climatic Test Chamber ,ESS Rapid-rate temp change chamber ,Walk-in Chamber ,Solar Test Chamber

Product Details

 

Two/three-zone Heat Shock Test Chamber  thermal shock testing

 

 

1.  Thermal Shock Chambers Overview:

 

Thermal shock test chamber is requisite testing equipment in metal, plastic, rubber, electronics and other industries. It is used for testing the material structure or composite material’s tolerance degree when exposed instantly in extremely high temperature and extremely low temperature environment continuously, so that whose chemical or physical damage due to thermal expansion and contraction can be detected in shortest time.

 

 

2. KOMEG Thermal Shock Chambers’ advantages:

 

1) the outside housing metal using car paint technology, the appearance of the atmosphere, easy to clean

 

2) use advanced foam technology and double layer insulation technology

 

3) Reasonable structure design, save space greatly under the premise of easy maintenance and use.  

 

4) Refrigeration system using international leading refrigeration technology and the introduction of the most advanced technology elbow, reducing welding point over 50%, improve the cleanliness of the refrigeration system.

 

5) Using the most advanced multi-rod piston refrigeration compressors, energy efficiency above 30%

 

6) The main electronic components and refrigeration components are used internationally renowned brands, product with high running stability.

 

7) Adopts the international advanced noise reduction technology, under full load operating conditions of the machine noise down to 65dB, enhance fluency and stability of the refrigeration system

 

8) Water and electricity separation design to reduce the failure rate of equipment, extend the service life of equipment.

  

 

3.  3-zone thermal shock chamber Specification

 

(1) KTS-A Series

 

Model

 

KTS-A Series

72A

100A

150A

200A

252A

300A

480A

Inside size(mm)

W

450

500

600

670

700

800

800

H

400

450

500

600

600

600

800

D

400

450

500

500

600

650

750

Outside size(mm)

W

1490

1540

1640

1720

1750

1850

1850

H

1790

1840

1890

2000

2000

2000

2200

D

1600

1700

1830

1850

1930

1980

2500

Test weight

5

10

12

15

18

20

20

Low Temp Chamber

 -55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC

Test Chamber

 -40ºC~+150ºC

High Temp Chamber

 +60ºC~+200ºC ,Within 20 min, Pre-heating time

Transition time

≤15S

Recovery time

High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample

Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample

≤ 5 min

Ambient Temp.

+5ºC~+35ºC

Power

AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires

 

(2) KTS-B Series

 

Model

 

KTS-B Series

72B

100B

150B

200B

252B

300B

480B

Inside size(mm)

W

450

500

600

670

700

800

800

H

400

450

500

600

600

600

800

D

400

450

500

500

600

650

750

Outside size(mm)

W

1490

1540

1640

1720

1750

1850

1850

H

1790

1840

1890

2000

2000

2000

2200

D

1600

1700

1830

1850

1930

1980

2500

Test weight(KG)

5

10

12

15

18

20

20

Low Temp. chamber  

 -70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min

Test. Chamber  

 -55ºC~+150ºC

High Temp. chamber temperature

 +60ºC~+200ºC,Preheating time: ≤20 min

Transition time

≤15S

Recovery time

High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample

Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample

≤ 5 min

Ambient Temp.

+5ºC~+35ºC

Power

AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires

 

(3) KTS-D Series

 

Model

 

KTS-D Series

72D

100D

150D

200D

252D

300D

480D

Inside size(mm)

W

450

500

600

670

700

800

800

H

400

450

500

600

600

600

800

D

400

450

500

500

600

650

750

Outside size(mm)

W

1490

1540

1640

1720

1750

1850

1850

H

1790

1840

1890

2000

2000

2000

2200

D

1600

1700

1830

1850

1930

1980

2500

Test weight

5

10

12

15

18

20

20

Low Temp Chamber

 -80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC

Test Chamber

 -65ºC~+150ºC

High Temp Chamber

 +60ºC~+200ºC ,Within 20 min, Pre-heating time

Transition time

≤15S

Recovery time

High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample

Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample

≤ 5 min

 

 

 

 

4. Thermal Shock Chamber Details Picture:

  two/three-zone Heat Shock Test Chamber thermal shock testingtwo/three-zone Heat Shock Test Chamber thermal shock testing 

 

 

Contact Supplier

Mr. Louis Long Chat Now
Telephone
86-769-83971185
Address
Building 12, Songshan Lake, Small and Medium-Sized Science and Technology Park Dongguan,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category