Anesthesia gas Ventilation machine anesthesia machine manufacturer from China
USD $1,700 - $2,700 /Unit
Min.Order:1 Unit
Wuhan Darppon Medical Technology Co., Ltd.
Anesthesia gas Ventilation machine anesthesia machine manufacturer from China
TECHNIQUES SPECIFICATIONS | |
Physical specifications | |
Display | 10.4'' LCD Display |
Mode: | pneumatically powered and electrically controlled system |
Trolley: | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications: | |
Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa |
safety valve | <12.5 kPa |
Respiratory Rate | 1 ~ 99 bpm |
Oxygen Concentration | 21% ~ 100% |
Maximum Minute ventilation | ≥18L / min |
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT |
Ventilator compliance | ≤30 Ml/kPa |
PEEP: | 0 ~ 1.0 kPa |
Ptr: | -10 ~ 10 hPa |
IMV frequency: | 1~20 bpm |
I/E Ratio: | 4:1~1:4, Has the inverse ratio ventilation |
Tidal Volume | Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml |
Inspiratory Plateau: | 0~1s |
Maximum Safety Pressure | ≤ 6.0kPa |
Sigh: | one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Pressure limit range: | 1.0~ 6.0kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa |
±0.2 kPa | |
Ventilation Volume alarm: | ≥ 18L/ MIN |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. | |
Operating conditions | |
Ambient temperature: | 10 ~ 40oC |
Relative humidity: | no higher than 80 % |
Atmospheric pressure: | 860 hPa ~ 1060 hPa |
Power requirement: | 100-120 Vac, 50/60 Hz; |
Attention: the AC power supply used for the anesthesia machine must be well grounded. | |
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. |
1. OEM/ODM service : Darppon offers OEM/ODM service for distributor to establish long term business relationship.
2. Warranty :Darppon offers 18 months free after-sale service for customers, and be responsible for life-time repair.
3. Technical support:Darppon offers professional engineers for customers on the technical support, and response within 12 hours