Chinese Anesthesia Machine with CE certificate 01D
USD $1,700 - $2,700 /Unit
Min.Order:1 Unit
Wuhan Darppon Medical Technology Co., Ltd.
Chinese Anesthesia Machine with CE certificate 01D
TECHNIQUES SPECIFICATIONS | |
Physical specifications | |
Screen: | 10.4 '' TFT Display Screen |
Suitable | Adult & Child |
Mode: | pneumatically powered and electrically controlled system |
Working Mode: | Closed; Semi-Closed; Semi-Open |
Circuit | Breathing circuit integrated standards |
Flowmeters: | 5 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min; Air: 0.1~10L / Min |
Trolley: | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Drawer unit | TWO drawers totally extractable |
Technical Specifications: | |
Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa. |
safety valve | <12.5 kPa |
Respiratory Rate | 1~99bpm |
Flowmeters: | 5 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min; Air: 0.1~10L / Min |
oxygen concentration in the mixed gas N2O/O2 | > 21% |
Oxygen Flush: | 25~75 L/min |
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV,PEEP, SIGH, MANUAL |
PEEP: | 1 ~ 10hPa |
Ptr: | -10~10hPa |
I/E Ratio: | 4:1 ~ 1:10, Has the inverse ratio ventilation |
Tidal Volume | 0 ~ 1500 ML |
Inspiratory Plateau: | 0~1s |
O2 Concentration: | 21%~100% |
Sigh: | one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Maximum safety pressure: | ≤ 12.5 kPa |
Pressure limit range: | 0 ~ 6.0 kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa |
±0.2 kPa | |
Tidal volume alarm: Audible and visual and with yellow and red color indicating | upper alarm: 50 to 2000ml, lower alarm: 0~1800ml |
Oxygen concentration alarm: Audible and visual and with yellow and red color indicating | upper alarm: 21% ~100%; lower alarm:10%~80% |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. |
1. OEM/ODM service : Darppon offers OEM/ODM service for distributor to establish long term business relationship.
2. Warranty :Darppon offers 18 months free after-sale service for customers, and be responsible for life-time repair.
3. Technical support:Darppon offers professional engineers for customers on the technical support, and response within 12 hours