0-150mm digital vernier caliper
USD $5 - $8 /Piece
Min.Order:1000 Pieces
Hangzhou Longma Hardware & Tools Co., Ltd.
SPECIFICATIONS
1.caliper length : 23.6cm
2.packing details:
QTY PER CTN | N.W/G.W | CTN SIZE |
50pcs | 17/19kg | 48*27*32 cm |
3.material: stainless steel(4cr13)
TECHNICAL SPECIFICATIONS
1.Outside Jaws: Measure External Length
2.Inside Jaws: Measure Internal Length
3.Measuring Range: 0-150mm/0-6in, 0~200mm/ 0~8 in
4.Resolution: 0.01mm/ 0.0005in
5.Accuracy: ± 0.02mm/ 0.001in (<100mm)
±0.03mm/0.001in(>100-200mm)
6.Repeatability: 0.01mm / 0.0005in
7.Max Measuring Speed: 1.5m/sec, 60in/sec
8.Measuring System: Linear Capacitance measuring system
9.Display: LCD Screen
10.Construction Material: Stainless Steel
11.Power: One alkaline lithium button cell battery 1.5v,TYPE LR44.
Capacity-180MAH
12.Working Temperature: 5°c-40°c/41 to 104 degree F
13.Note: Accuracy affected in environments exceeding 80% relative humidity.
•APPLICATIONS
1.Operation : slider can be removed only after the locking screw (#10) is loosened.
2.Basic measuring methods :
1) loosen the locking screw
2) Press "ON " button, select sae or metric measurement by pressing "MM/INCH" button.
Pressing "MM/INCH" button after measurement will display the sae / metric conversion.
3)To reset display to zero, close external measuring jaws, then press "ZERO" button.
MAINTENANCE INSTRUCTIONS
1. Keep the calliper clean and dry (liquid can damage the slider)
2. Use a clean, dry cloth to clean all surfaces -do not use solvents or solvent based cleaners.
3. To save power, turn off the unit when not in use.
Avoid contact with electricty and /or electronic devices
BATTERY REPLACEMENT
Flashing display indicates low battery. To replace battery, remove battery cover by sliding cover in
the direction indicated and replace battery with positive side facing out.
TROUBLE SHOOTING
Falure | Cause | Measure |
Display flashes | Low battery | Replace battery |
Display does not change when slider is moved | System locked | Remove battery and replace after 30 seconds to reset system |
Accuracy less than +/-0.001mm | Dirt in the sensor | Remove slider cover and its assembly, clean with compress air 5kgs/cm2 |
No display on LCD | 1. improper battery position 2. Low battery | 1. Remove battery cover and check battery position 2. Replace battery. |