Three-boxes Rapid temperature changes test chamber
USD $8,500 - $9,500 /Piece
Min.Order:10 Pieces
Guangdong Sanwood Environmental Chambers Co., Ltd.
Chapter 01, Dimension & Notice:
Testing Limited | Following samples are forbidden to test and store: |
Volume and Dimension | 225L |
Internal Testing Room | W750×H600×D500 mm is the internal testing space size; |
Outer Fully Dimension | W1450×H1750×D1100mm is the outer fully machine size |
Chapter 02, Performance:
Test Condition | 01. Environmental temperature: +5℃~+35℃ |
Temperature Range | -40℃~+150℃ |
Test Method: | 01. No samples in cabinet(unless state in advance) |
Temperature Fluctuation | ≤0.5℃ (Note: if measured with GB/T5170.2-1996 fluctuation ≤±0.25℃) |
Temperature Deviation | Better than ±1.5℃ |
Temperature Uniformity | 01. ≤2℃ |
Maximum Rate of Temperature Change | Mechanical refrigeration, standard load, -45 ~ + 125 ℃, linear, every 5min average error is less than 10%. |
Standard Load | 15kg Aluminium and no heat |
Temperature Range | 20%RH~98%RH (control range is refer to following picture) |
Relative Humidity Deviation | 01. ±1.0%RH(humidity > 75%RH) |
Noise | A sound/voice level≤70dB(A); (The distance is 1 metre to the door and the height is 1.2m to the ground, freely space) |
Meet test Methods | 01.GB/T2423.1-2008(IEC60068-2-1:2007) Low temperature test method |
Chapter 03, Structure Features:
Insulation Structure | 01. Wall: two-sided galvanized steel, surface with spray treatment (ESPEC standard color) |
Air Conditioning Access | Fans, heaters, evaporators, drainage device, humidifier, dry preventer, wet bulb temperature sensor, wet sink |
Test Cabinet Standard Configuration | 01. Fairlead: two fairlead withφ100mm diameter on each side cabinet, located at the center of side wall |
Door | 01. Hinged doors, hinges on the left box (when facing the front of the box) |
Control Panel | The controller display ; Buttons, over-temperature protection device ; USB interface; |
Mechanical Room | The machine room comprises: Refrigeration units, drain devices, fans, power distribution control cabinet, Humidification and water measuring humidity control device |
Distribution Control Cabinet | Cooling fan ; Buzzer ; Distribution boards ; RS-485, RJ-45 Ethernet physical interface (equipped with monitoring software together) ; Main Power Circuit Breaker; |
Heater | Nickel-chromium alloy heating wire heater ; Heater control: non-contact and other periodic pulse width modulation, SSR (solid state relay); |
Humidifier | 01. Basin heated humidification method |
Chapter 04, Electrical Cooling System:
Work Method | Mechanical compression binary cascade refrigeration mode |
Condensation Method | Water-cooled (equipped with the cooling water flow device automatically can be adjustable) |
Refrigeration Compressors | Mechanical compressor |
Evaporator | Finned heat exchanger |
Throttling Device | Electronic expansion valve |
Evaporative Condensers | Brazed plate heat exchanger |
Chiller Control ways | 01. Control system automatically adjusts the refrigerator to run the best energy-saving operating mode based on test conditions |
Figures Refrigeration System Conditions | Refrigeration system controller digital display high and low pressure, exhaust temperature and compressor operating current |
Refrigerant | R404a / R23 (Ozone depletion indices are zero) |
Others | The main components are international brand products; Cooling water filters (user-site installation) |
CHAPTER 05, Following Terms Should Be Ensured : Optional Accessories: The pricelist does not include the below following accessories, that should be specified in the contract.
Fairlead: | The diameter of the fairlead is φ50 or φ100,users can customize the position and quantity of it as long as it will not affect the equipment performance. |
Monitoring Software: | For remote monitor and equipped with RAS-2003 software and one RS-485/RS-232 converter. |
Software Working Condition: | Compatible PC IBM with PⅡ CPU and 128M ROM. |
Model | SM-500-3P-B | SM-1000-3P-B | SM-2000-3P-B |
Interior Dimension (W×H×D) | 120×60×70cm | 150×70×100cm | 155×120×120cm |
Exterior Dimension (W×H×D) | 210×222×175cm | 262×179×286cm | 267×231×348cm |
Structure | Two chambers design(the hot chamber or the cold chamber) . | ||
Damper device | Forced air drived damper | ||
Material | SUS304 Stainless steel plate | ||
Refrigeration | Cascade refrigeration system | ||
Cooling system | Water cooling | ||
Temperature range | -70°~200°C | ||
Temperature fluctuation | ±0.5°C | ||
Humidity range | 40~95%RH | ||
Preheating temperature limit | 200°C | ||
Heating rate | 0°C~200°C/30 min | ||
Precooling temperature limit | -70°C | ||
Cooling rate | 0°C~ -70°C/90 min | ||
Temperature recovery time | within 10 minutes | ||
Test area bearing | 50 kg | ||
Shelf bearing | 20 kg | ||
Setting range | Temperature: -100°C~200°C/TIME:OHIM~999h/CYCLE:0 ~9999 | ||
Output mode | PID+SSR(control method) | ||
Power supply | AC 220/380V, 50/60HZ | ||
Weight | About 1,700 kg | About 3,000 kg | About 4,000 kg |
/watch?v=G8Rm8AbJ-Ng
Sanwood tensile testing Equipments :
http://sanwood.en.china.cn/product/60127432596-800480984/tensile_machine.html
Sanwood climatic Testing Chambers :
http://sanwood.en.china.cn/product/60127432596-800480984/tensile_machine.html
Sanwood xenon lamp Test Chamber :
http://sanwood.en.china.cn/product/60127432596-800480984/tensile_machine.html