CE certificated Rapid temperature chamber
USD $8,500 - $9,500 /Set
Min.Order:1 Set
Guangdong Sanwood Environmental Chambers Co., Ltd.
Chapter 01, Dimension & Notice:
Testing Limited | Following samples are forbidden to test and store: |
Volume and Dimension | 225L |
Internal Testing Room | W750×H600×D500 mm is the internal testing space size; |
Outer Fully Dimension | W1450×H1750×D1100mm is the outer fully machine size |
Chapter 02, Performance:
Test Condition | 01. Environmental temperature: +5℃~+35℃ |
Temperature Range | -40℃~+150℃ |
Test Method: | 01. No samples in cabinet(unless state in advance) |
Temperature Fluctuation | ≤0.5℃ (Note: if measured with GB/T5170.2-1996 fluctuation ≤±0.25℃) |
Temperature Deviation | Better than ±1.5℃ |
Temperature Uniformity | 01. ≤2℃ |
Maximum Rate of Temperature Change | Mechanical refrigeration, standard load, -45 ~ + 125 ℃, linear, every 5min average error is less than 10%. |
Standard Load | 15kg Aluminium and no heat |
Temperature Range | 20%RH~98%RH (control range is refer to following picture) |
Relative Humidity Deviation | 01. ±1.0%RH(humidity > 75%RH) |
Noise | A sound/voice level≤70dB(A); (The distance is 1 metre to the door and the height is 1.2m to the ground, freely space) |
Meet test Methods | 01.GB/T2423.1-2008(IEC60068-2-1:2007) Low temperature test method |
Chapter 03, Structure Features:
Insulation Structure | 01. Wall: two-sided galvanized steel, surface with spray treatment (ESPEC standard color) |
Air Conditioning Access | Fans, heaters, evaporators, drainage device, humidifier, dry preventer, wet bulb temperature sensor, wet sink |
Test Cabinet Standard Configuration | 01. Fairlead: two fairlead withφ100mm diameter on each side cabinet, located at the center of side wall |
Door | 01. Hinged doors, hinges on the left box (when facing the front of the box) |
Control Panel | The controller display ; Buttons, over-temperature protection device ; USB interface; |
Mechanical Room | The machine room comprises: Refrigeration units, drain devices, fans, power distribution control cabinet, Humidification and water measuring humidity control device |
Distribution Control Cabinet | Cooling fan ; Buzzer ; Distribution boards ; RS-485, RJ-45 Ethernet physical interface (equipped with monitoring software together) ; Main Power Circuit Breaker; |
Heater | Nickel-chromium alloy heating wire heater ; Heater control: non-contact and other periodic pulse width modulation, SSR (solid state relay); |
Humidifier | 01. Basin heated humidification method |
Chapter 04, Electrical Cooling System:
Work Method | Mechanical compression binary cascade refrigeration mode |
Condensation Method | Water-cooled (equipped with the cooling water flow device automatically can be adjustable) |
Refrigeration Compressors | Mechanical compressor |
Evaporator | Finned heat exchanger |
Throttling Device | Electronic expansion valve |
Evaporative Condensers | Brazed plate heat exchanger |
Chiller Control ways | 01. Control system automatically adjusts the refrigerator to run the best energy-saving operating mode based on test conditions |
Figures Refrigeration System Conditions | Refrigeration system controller digital display high and low pressure, exhaust temperature and compressor operating current |
Refrigerant | R404a / R23 (Ozone depletion indices are zero) |
Others | The main components are international brand products; Cooling water filters (user-site installation) |
CHAPTER 05, Following Terms Should Be Ensured : Optional Accessories: The pricelist does not include the below following accessories, that should be specified in the contract.
Fairlead: | The diameter of the fairlead is φ50 or φ100,users can customize the position and quantity of it as long as it will not affect the equipment performance. |
Monitoring Software: | For remote monitor and equipped with RAS-2003 software and one RS-485/RS-232 converter. |
Software Working Condition: | Compatible PC IBM with PⅡ CPU and 128M ROM. |
Model | SM-500-3P-B | SM-1000-3P-B | SM-2000-3P-B |
Interior Dimension (W×H×D) | 120×60×70cm | 150×70×100cm | 155×120×120cm |
Exterior Dimension (W×H×D) | 210×222×175cm | 262×179×286cm | 267×231×348cm |
Structure | Two chambers design(the hot chamber or the cold chamber) . | ||
Damper device | Forced air drived damper | ||
Material | SUS304 Stainless steel plate | ||
Refrigeration | Cascade refrigeration system | ||
Cooling system | Water cooling | ||
Temperature range | -70°~200°C | ||
Temperature fluctuation | ±0.5°C | ||
Humidity range | 40~95%RH | ||
Preheating temperature limit | 200°C | ||
Heating rate | 0°C~200°C/30 min | ||
Precooling temperature limit | -70°C | ||
Cooling rate | 0°C~ -70°C/90 min | ||
Temperature recovery time | within 10 minutes | ||
Test area bearing | 50 kg | ||
Shelf bearing | 20 kg | ||
Setting range | Temperature: -100°C~200°C/TIME:OHIM~999h/CYCLE:0 ~9999 | ||
Output mode | PID+SSR(control method) | ||
Power supply | AC 220/380V, 50/60HZ | ||
Weight | About 1,700 kg | About 3,000 kg | About 4,000 kg |
COMPANY INFORMATION
Quality control
We have independent quality control department, each production process will pass through the three test. If it is not qualified products, it will be returned to re-production.
Cost
Manufacture --- Dealer --- Foreign company --- Buyer
Manufacture --- Buyer
Service:
PARTNERS AND SERVICE
AFTER SALES SERVICE
ALL OF OUR TEST CHAMBERS HAS ONE YEAR WARRANTY.
SANWOOD REPAIR THE EQUIPMENT IS UNDER THE ORDINARY USAGE AND ARISE ANY HARDWARE PROBLEMS WHICH CAUSED BY PRODUCT ITSELF, RATHER THAN HUMAN ERROR.
FIRSTLY, WE CAN PROVIDE THE SPARE PARTS WITH YOU. AND ALSO PROVIDE THE SOLUTION ABOUT THE TROUBLE OF THE EQUIPMENTS.
SECONDLY, PLEASE SEND BACK THE EQUIPMENT, WHICH WILL BE REPAIRED BY OUR COMPANY.
LASTLY, WE WOULD LIKE TO APPOINT OUR TECHNICAL ENGINEER TO YOUR COMPANY TO REPAIR THE EQUIPMENT.
♥ Want to know more information welcome to contact us now!
And welcome to our company! We display more new design in our showroom.
♥ Main web site: .tw
Skype: climatic-chamber007