medical low price syringe pump single channel
USD $1 - $1,000 /Piece
Min.Order:1 Piece
syringe pump(JAZ-1800G)
Four working modes: Rate mode, Time mode, Weight mode and Drug library mode.
174 Drugs with 10 Categories of D rug Libarary : Cardiovascular Sys, Respiratory Sys, Antibiotic Sys, Alimentary Sys, Nervous Sys, Analgesic Sys, Urinary Sys, Blood Sys, Endocrine Sys, Anaesthetic Sys.
17Units of Dose:ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, IU/h, U/kg/h, ng/kg/min, can make drug dispensing more convenient and safer.
ICU Infusion Workstation: Combines four syringe pumps and one infusion pump with the Infusion Support into one ICU Infusion Workstation, sharing a Power Interface.
Stackable up to the maximum 8 channels.
Transfer the message between the Nurse-call System and the pumps.
Bolus function.
SPECIFICATIONS :
Compatible Syringe:Any standard syringe with 5ml, 10ml, 20ml, 30ml and 50ml, 60ml
Accuracy :±2% ( Any manufacturers of syringes, right after calibration )
Delivery Rate Range :
5ml: 0.1ml/h ~ 200.0ml/h (0.1ml/h step)
10ml: 0.1ml/h ~ 400.0ml/h (0.1ml/h step)
20ml(30ml): 0.1ml/h ~ 800.0ml/h (0.1ml/h step)
50ml(60ml): 0.1ml/h ~ 1800.0ml/h (0.1ml/h step)
Time setting mode range :
Volume: 0.1 – 200.0ml, 0.1ml step.
Time: 0.1 – 999.9min, 0.1min step.
Drug Library setting mode range :
Sol. volume: 0.1 – 199.9ml, 0.1ml step.
Drug mass: 0.1 – 999.9ml, 0.1 ml step.
Dose: 0.001 – 9999, 0.001 step.
Units of Dose: ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, IU/h, U/kg/h, ng/kg/min .
Weight: 0.1- 300.0kg, 0.1kg step.
Bolus setting mode range :
Bolus. Volume: 0.1ml – 60.0ml, 0.1ml step
Bolus Rate: 5ml: 0.1ml/h – 200.0ml/h,0.1ml/h step
10ml: 0.1ml/h – 400.0ml/h,0.1ml/h step
20ml: 0.1ml/h – 800.0ml/h,0.1ml/h step
30ml: 0.1ml/h – 1200.0ml/h,0.1ml/h step
50ml(60ml): 0.1ml/h – 1800.0ml/h,0.1ml/h step
Purge :50ml(60ml): 1800.0ml/h, 20ml(30ml): 800.0ml/h, 10ml: 400.0ml/h , 5ml: 200.0ml/h
KVO Rate: 0.1ml/h – 1.0ml/h, 0.1ml/h step
Alarms: Near empty, Syringe empty, Volume complete (a volume limit has been set ), Occlusion, Syringe loose, Syringe dislocated, Operation error, Low battery and other device failures.
Power Supply:
AC power supply: AC 100 to 240V±10% , 50/60HZ
Internal Lithium Battery: 11.1V, 2000mAh. Approximmately 8 hours of continuous operation on a new and fully charged battery running at 5ml/h.
Power Consumption: ≤25VA
Safety level: ClassI, Type CF
Dimensions: 230mm(L)×150mm(W)×125mm(H)
Net Weight: Approximately. 2.2kg
Operating Conditions: Ambient temperature: 5 to 40°C Relative humidity: 20 to 90%
Storage Condition: Ambient temperature: -10 to 55°C Relative humidity: 10 to 90%
Accessories: AC power line, Operational manual