mini kwh meter GH100
Negotiable /Set
Min.Order:1 Set
Hangzhou Yasian Technology Co., Ltd.
Din rail single phase energy meter
1,Overview
Din rail single phase energy meter use LCD display,the clock,tariff times etc parameters could be set by end user,and with electrical energy pulse function;RS485 Modbus RTU protocol.
Small size,high precision,good reliability,easy installation;It is designed complying with international standard IEC 62052 and IEC 62053(GB/T17215,GB/T17883).
2,Product Specification
Product Series | Items | Accuracy | Rated voltage | Current range | Pulse constant |
Din rail single phase energy meter | GH100 | 1.0 | 220V | 1.5(6)A | 12800imp/kWh |
5(20)A | 3200imp/kWh | ||||
GH100-E/C | 10(40)A | 1600imp/kWh | |||
GH100-E/CF | 20(80)A | 800imp/kWh |
3,Technical Parameter
Parameter | Technical value | ||||
GH100 | GH100-E/C | GH100-E/CF | |||
Accuracy | Active energy:1.0 class,reactive energy:2.0 class | ||||
Rated voltage | 3*230V/400V | ||||
Current range | 1.5(6)A,5(20)A,10(40)A,20(80)A | ||||
Voltage supply | normal:0.9~1.1Un;maximal:0.7~1.2Un | ||||
Frequency | 50Hz or 60Hz | ||||
Starting current | Without CT | 0.004Ib | |||
With CT | 0.002In | ||||
Power consumption | For voltage | ≤5VA/phase | |||
For current | <4VA/phase | ||||
Pulse output | Pulse width:80ms±20ms;open-collector photo-coupler pulse | ||||
Digital communication | Digital communication | RS485,MODBUS-RTU(customizable) | |||
Clock error | Clock error | ≤0.5s/d | |||
Environment | normal: -10C ~ +45C, maximal: -20C ~ +55C, storage: -40C ~ +70C | ||||
Relative humidity | ≤95%( without dewing) | ||||
Normal life span(h) | ≥50000 | ||||
Outline (L×W×H) | 76×91×74(mm) | ||||
Note:
GH100-E/CFwith RS485 communication;active&reactive energy pulse output,tariff times;GH100-E/Cwith RS485 communication and pulse output function;
GH100 without RS485 communication function