wall mounted magnetic flow meter converter Supplier's Choice
USD $199 - $1,999 /Set
Min.Order:1 Set
Kaifeng Qingtianweiye Flow Instrument Co., Ltd.
Intelligent electromagnetic flow meter is hallmarked by its high performance and reliability based on successful, field-proven technology. It is being widely used in industries such as petroleum, chemical engineering, iron and steel, food, electricpower, paper making, water treatment, petrochemical, medicine etc.
Model | DN6~DN3000mm | ||
---|---|---|---|
Nominal Pressure | 0.6~1.6MPa(2.5Mpa/4.0Mpa/6.4Mpa...42Mpa) | ||
Accuracy | ±0.5%,±0.3%or±0.2% are selectable | ||
Liner material | Teflon,PFA,F46,Neoprene,Polyurethane | ||
Electrode Type | General type ,scraper type and replaceable type | ||
Electrode material | Stainless steel SUS316,Hastelloy C,Titanium,Tantalum Platinumiridium, Stainless steel covered with tungsten carbide | ||
Mediem temperature | Integrate type | -20°C~+60°C | |
Remote type | Neoprene & Polyurethane Liner | -10°C~+80°C | |
PTFE Liner /PFA Liner /F46 Liner | -10°C~+160°C | ||
Ambient Temperature | -25°C ~+ 60°C | ||
Ambient Humidity | 5~100%RH(relative humidity) | ||
Medium Electrical conductivity | >=5u s/cm | ||
Measuring Range | 1500:1,flow rate<15m/s | ||
Structure type | Integral type,remote type,submersible type,ex-proof type | ||
Protection Class | IP65,IP68(optional) | ||
Ex-proof Mark | ExmdⅡT6 | ||
Product Standard | JB/T 9248-1999 Electormagnetic Flowmeter |
Electrode material | Applications |
---|---|
sainless steel SUS316 | Applicable in water,sewage and corrosive mediums. |
Widely used in industries of petrol,chemistry,carbamide,etc | |
Stainless steel covered with tungsten carbide | Applicable in mediums of no corrosive and low abrasion. |
Hastelloy B(HB) | Having strong resistance to hydrochloric acid of any consistance which is below bioling piont. |
Also resistable against vitriol,phosphate, | |
hydrofluoricacid,organic acid etc which are oxidable acid,alkali and non-oxidable salt. | |
Hastelloy C(HC) | Be resistant to oxidable acid such as nitric acid,mixed acid |
as well as oxidable salt such as Fe+++,Cu++aStnd sea water | |
Titanium | Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable |
Not resistant to a pure reducing acid(such as sulphuric acid,hydrochloric | |
But if acid contains antioxidant is greatly reduce corrosion. | |
Tantalum | Having strong resistance to corrosive mediums that is similar with glass |
Almost is applicable to all chemical mediums. | |
Except for hydrofluoric acid,oleum and alkali. | |
Platinum-iridium | Almost be applicable in all chemical mediums except for ammonium salt. |
Pipe Size | Min.Flow Rate (0~0.5m/s) | Min.Flow Rate (0~10m/s) | |
---|---|---|---|
mm | inch | L/min,m3/h | L/min,m3/h |
10 | 3/8 | 0 ~ 2 L/min | 0 ~ 40 L/min |
15 | 1/2 | 0 ~ 5 L/min | 0 ~ 100 L/min |
20 | 3/4 | 0 ~ 7.5 L/min | 0 ~ 150 L/min |
25 | 1 | 0 ~ 10 L/min | 0 ~ 200 L/min |
32 | 1.25 | 0 ~ 20 L/min | 0 ~ 400 L/min |
40 | 1.5 | 0 ~ 30 L/min | 0 ~ 600 L/min |
50 | 2 | 0 ~ 3 m3/h | 0 ~ 60 m3/h |
65 | 2.5 | 0 ~ 6 m3/h | 0 ~ 120 m3/h |
80 | 3 | 0 ~ 9 m3/h | 0 ~ 180 m3/h |
100 | 4 | 0 ~ 12 m3/h | 0 ~ 240 m3/h |
125 | 5 | 0 ~ 21 m3/h | 0 ~ 420 m3/h |
150 | 6 | 0 ~ 30 m3/h | 0 ~ 600 m3/h |
200 | 8 | 0 ~ 54 m3/h | 0 ~ 1080 m3/h |
250 | 10 | 0 ~ 90 m3/h | 0 ~ 1800 m3/h |
300 | 12 | 0 ~ 120 m3/h | 0 ~ 2400 m3/h |
350 | 14 | 0 ~ 165 m3/h | 0 ~ 3300 m3/h |
400 | 16 | 0 ~ 225 m3/h | 0 ~ 4500 m3/h |
450 | 18 | 0 ~ 300 m3/h | 0 ~ 6000 m3/h |
500 | 20 | 0 ~ 330 m3/h | 0 ~ 6600 m3/h |
600 | 24 | 0 ~ 480 m3/h | 0 ~ 9600 m3/h |
700 | 28 | 0 ~ 660 m3/h | 0 ~ 13200 m3/h |
800 | 32 | 0 ~ 900 m3/h | 0 ~ 18000 m3/h |
900 | 36 | 0 ~ 1200 m3/h | 0 ~ 24000 m3/h |
1000 | 40 | 0 ~ 1350 m3/h | 0 ~ 27000 m3/h |