Surge protection high frequency online UPS
USD $80 - $500 /Unit
Min.Order:5 Units
Sako Electrical Group Co., Ltd.
SAKO SKG-VSERIESHF ONLINE UPS SPECIFICATION | |||||||||
APPLICATION: | |||||||||
small network servers and other IT equipment | |||||||||
Features and Benefits | |||||||||
1) High frequency and double conversion on-line technology | |||||||||
2)Intelligent MCU control | |||||||||
3) Wide input voltage range | |||||||||
4) UPS start up without battery | |||||||||
5) Cold start | |||||||||
6) Advanced battery management | |||||||||
7) Automatic battery charge in UPS off mode | |||||||||
8) Lightning and surge protection | |||||||||
9) Short circuit and overload protection | |||||||||
10) Fan speed auto control when loads varies | |||||||||
11) Optional extension battery pack | |||||||||
12) EMI/RFI noise filter | |||||||||
13) Smart RS232,USB,RJ45 communication with monitoring software | |||||||||
14) Optional SNMP Card slot | |||||||||
15)with LCD and LED two type front panel | |||||||||
16)In LCD model, nominal bypass ECO setting function | |||||||||
17)In LCD model, Generator setting function | |||||||||
18)In LCD model, Output voltage 220V,230V,240V setting function | |||||||||
19) EPO control system option | |||||||||
| SKG-V1K | SKG-V1KS | SKG-V2K | SKG-V2KS | SKG-V3K | SKG-V3KS | SKG-V6K | SKG-V6KS | |
Specifications | |||||||||
Capacity(VA/W) | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | 6000VA/4200W | |||||
INPUT Feature | |||||||||
Battery voltage(Vdc) | 24 | 48 | 96 | 144 | |||||
Voltage Range(Vac) | 176~286VAC @ full load (138~300VAC @ half load) | ||||||||
Frequency Range(Hz) | 46 ~ 54Hz / 56 ~ 64Hz | ||||||||
Number of phases | single phase&earth ground | ||||||||
Power Fator | ≥0.98, Full RCD Load | ||||||||
Generator Input | Support | ||||||||
Output feature | |||||||||
Voltage | 220/230/240VAC± 1% | ||||||||
Frequency ( Battery Mode ) | 50/60Hz ± 0.1 Hz | ||||||||
Frequency(Hz) | 50±0.2% (battery mode) | ||||||||
Wave form | Pure Sine wave THD<4% | ||||||||
Overload Capacity(Line Mode) | >=110%; 2mins, Then transfer to bypass and Alarm, >=150%; 10 S, Then transfer to bypass, turn off output after 1mins and Alarm | ||||||||
Overload capacity( Battery Mode ) | > =110 %; 30 S, Then turnoff output and Alarm, > =120 %; 1S, Then turnoff output and Alarm | ||||||||
Output mode | IEC x2 | IEC x4 | IEC x4 | Terminal Block | |||||
Battery | |||||||||
Battery Type | 12V/9AH | Depending on the capacity of external batteries | 12V/9AH | Depending on the capacity of external batteries | 12V/5AH | Depending on the capacity of external batteries | 12V/9AH | Depending on the capacity of external batteries | |
Numbers of Batteries | 2 | 4 | 8 | 12 | |||||
Backup Time (Half Load) | >10 min | >10 min | >10 min | >12 min | |||||
Recharge Time (to 90%) | 5 Hours | 5 Hours | 3Hours | 3Hours | |||||
Charging Current (Max.) | 1.0A | 3.0A | 1.0A | 3.0A | 2.0A | 6.0A | 2.0A | 6.0A | |
Rated Charging Voltage | 26.927.9vdc | 53.655.5vdc | 108111vdc | 161 ~164Vdc | |||||
Other feature | |||||||||
EFFICIENCY(AC /Battery Mode) | 93%-92% | ||||||||
TRANSFER TIME(AC to DC) | Zero | ||||||||
TRANSFER TIME(Inverter to Bypass) | 4ms (Typical ) | ||||||||
AUDIBLE ALARM(Battery Mode) | Sounding every 4 seconds | ||||||||
INDICATOR(LED Version) | Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault | ||||||||
INDICATOR(LCD Version) | Load / Battery / Input / Output / Operating Mode Information | ||||||||
Protections | Low battery protection,overload protection,short-circuit protection,overheated protection | ||||||||
Ambient temperes | 0-40 | ||||||||
Reative humidity | |||||||||
Products Size(mm) | L208*W145*H221mm | L462*W191*H298mm | L462*W191*H347mm | L526*W240*H489mm | |||||
Products Weight(KG) | 12 | 5.2 | 23 | 10.8 | 25 | 12 | 90 | 35 |