three phase online UPS 10K/15K/20K(LCD display)
Negotiable /Piece
Min.Order:5 Pieces
Sako Electrical Group Co., Ltd.
SAKO HIGH FREQUECY ONLINE UPS SKG-6-20KVA | ||||||||
Application: | ||||||||
Small network server and other IT equipment | ||||||||
Feature: | ||||||||
1)High frequency and double conversion on-line technology | ||||||||
2)Fully digitilized DSP control | ||||||||
3)Advanced PFC | ||||||||
4)Wide input voltage range | ||||||||
5)Parallel Redundancy | ||||||||
6)LCD display option | ||||||||
7)Parallel capacity | ||||||||
8)Advanced Battery Management | ||||||||
9)Automatically charging in ups OFF mode | ||||||||
10)Lightning and surge protection | ||||||||
11)Short circuit and overload protection | ||||||||
12)Fan speed auto control when loads varies | ||||||||
13)EMI/RFI noise filter | ||||||||
14)Smart RS232 communication port | ||||||||
15)Optional SNMP cards | ||||||||
16)LCD model:SKG-X | ||||||||
Series | SKG 6~20K | |||||||
Model | SKG-6K | SKG-10K | SKG-R6K | SKG-R10K | SKG-T10K | SKG-T15K | SKG-T20K | |
Capacity | 6KVA/4.2KW | 10KVA/7KW | 6KVA/4.2KW | 10KVA/7KW | 10KVA/7KW | 15KVA/10.5W | 20KVA/14KW | |
Input | Voltage Range | 176±5VAC~276±5VAC | 304±5VAC~478±5VAC | |||||
Frequency Range | 46~54HZ±0.5HZ or 56~64HZ±0.5HZ auto sensing | |||||||
Phase | Single phase | Three phase | ||||||
Power Factor | ≥0.98 | ≥0.95 | ||||||
Voltage Range | 220Vac±1% | |||||||
Output | Phase | Single phase | ||||||
Frequency Range | 50HZ±0.2%(battery mode) | |||||||
THD (linear load) | 2% | |||||||
THD (non-linear load) | 6% | |||||||
Overload Capability | 105%~130% 10min rurn to bypass mode;130% 1s rurn to bypass mode | |||||||
Crest Factor | 3:1(max) | |||||||
Short Circuit Protection | 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode) | |||||||
5 cycles turn off inverter, provide alarm (battery mode) | ||||||||
input fuse blown or breaker action (bypass mode) | ||||||||
Waveform | Pure sine wave | |||||||
Transfer Time Between AC Mode and Battery Mode | Zero transfer time | |||||||
Transfer Time Between AC Mode and Bypass Mode | Zero transfer time | |||||||
Efficiency | ≥88% | |||||||
Battery | Model | 12V sealed lead acid maintenance free | ||||||
DC Voltage | 240VDC | |||||||
Configuration | 20×12V/7AH | External battery bank | ||||||
Backup Timehalf load | 20min | 13min | Depends on the external battery capacity | |||||
Backup Timefull load | 7min | 5min | ||||||
Charge Current(standard unit) | 1A | N/A | ||||||
Charge Current(long time unit) | 5A | |||||||
Recharge Time | 90% capacity after 8 hrs charging | |||||||
Communication Interface | RS232;SNMP(ortional) | |||||||
Parallel port | Parallel availability for redundancy and load sharing up to three units | |||||||
LCD Indication | LCD: 1.Inpur voltage/frequency,battery voltage,output voltage/frequency,loadwatt,Va value and percent,inverter temperature 2.Operation mode auch ason line,on battoron bypass LED: 1.Green LED for normal operation, 2. Yellow LED for warning condition, 3.Red LED for abnormal operation | |||||||
LED Indication | Mode, load or battery capacity | |||||||
Noise Level | ≤55dB | |||||||
Environment | Temperature | 0~40 | ||||||
Humidity | 0%~95%(Non-condensing) | |||||||
Altitude | 1500m | |||||||
Storage Temperature | 0~40 | |||||||
Other | Standard unit Net/Gross Weight | 91/103Kg | 94/106Kg | N/A | N/A | 95/109Kg | N/A | |
Long Time Unit Net/Gross Weight | 36/46Kg | 38/48Kg | 22/25Kg | 22/25Kg | 39/51Kg | 60/74Kg | ||
Dimension(W×D×H)mm | 260×570×717 | 440×656×176 | 440×656×176 | 260×570×717 | 320×620×950 | |||
Packing(W×D×H)mm | 430×700×845 | 580×790×336 | 580×790×336 | 430×700×845 | 410×717×1050 |