XLPE Insulated No Halogen/ Low Smoke /Fire Retardant Power Cable for Rated Voltage up to and Including 35kv
USD $0.1 - $500 /Meter
Min.Order:500 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
Product Description:
XLPE Insulated No Halogen Low Smoke Fire Retardant Power Cable For Rated Voltage Up To And Including 35KV
Application:
This product is produced in accordance with RCCE and NF series standards and IEC60502IEC60332-3IEC60754IEC601034, etc standard. After fired, this product cannot spread combustion and possesses no halogen, low smoke, no toxicity, no corrosion and so on characteristics. It is suitable for nuclear power station, underground facilities, tunnel, high-rise and broadcast television station, etc. Fields. It is laid at electric power circuit with 35KV of rated voltage and is used as power transmission/distribution.
Type | Cores | Rated Voltage KV | |||||||||||||||||
0.6/1 | 1.8/3 | 3.6/6 6/6 | 6/10 8.7/10 | 8.7/15 | 18/20~26/35 | ||||||||||||||
Nominal Cross-sectional area mm 2 | |||||||||||||||||||
WDZA-YJY WDZB-YJY WDZC-YJY WDZA-YJLY WDZB-YJLY WDZC-YJLY | 1 | 2.5~1000 | 10~1000 | 25~1000 | 25~1000 | 35~1000 | 50~1000 | ||||||||||||
WDZA-YJY33 WDZB-YJY33 WDZC-YJY33 WDZA-YJLY33 WDZB-YJLY33 WDZC-YJLY33 | 10~10000 | 10~10000 | 25~10000 | 25~10000 | 35~10000 | 50~10000 | |||||||||||||
WDZA-YJY43 WDZB-YJY43 WDZC-YJY43 WDZA-YJLY43 WDZB-YJLY43 WDZC-YJLY43 | 10~10000 | 10~10000 | 25~10000 | 25~10000 | 35~10000 | 50~10000 | |||||||||||||
WDZA-YJY WDZB-YJY WDZC-YJY WDZA-YJLY WDZB-YJLY WDZC-YJLY | 2 3 4 5 3+1 3+2 4+1 | 2.5~400 | 10~300 | 25~300 | 25~300 | 25~300 | 25~300 | ||||||||||||
WDZA-YJY23 WDZB-YJY23 WDZC-YJY23 WDZA-YJLY23 WDZB-YJLY23 WDZC-YJLY23 | 4~400 | 10~300 | 25~300 | 25~300 | 25~300 | 25~300 | |||||||||||||
WDZA-YJY33 WDZB-YJY33 WDZC-YJY33 WDZA-YJLY33 WDZB-YJLY33 WDZC-YJLY33 | 4~400 | 10~300 | 25~300 | 25~300 | 25~300 | 25~300 | |||||||||||||
WDZA-YJY43 WDZB-YJY43 WDZC-YJY43 WDZA-YJLY43 WDZB-YJLY43 WDZC-YJLY43 | 4~400 | 10~300 | 25~300 | 25~300 | 25~300 | 25~300 | |||||||||||||
Rated Voltage KV | 0.6 | 1.8 | 3.6 | 6 | 8.7 | 12 | 18 | 21 | 26 | ||||||||||
Test voltage KV | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 | ||||||||||
Item of test | Unit | Performance | |||||||||||||||||
Density of smoke test Min. light transmittance | % | 60 | |||||||||||||||||
Causticity of test Min. PH value Max. electric conductibility | μ S/mm | 4.3 10 | |||||||||||||||||
Combustion test of bundled cable grade of test Time of supply fire Total volume of combustible material per meter Length affected by combustion | Min l/m m | A 40 7 | B 40 3.5 | C 20 1.5 | |||||||||||||||
< 2.5 | |||||||||||||||||||
Test item | Unit | Performance | |||||||||||||||||
Insulation | Sheath | ||||||||||||||||||
Before ageing test | |||||||||||||||||||
Min. tensile force | N/mm 2 | 12.2 | 9 | ||||||||||||||||
Min. elongation of rupture | % | 200 | 125 | ||||||||||||||||
After aged by oven | |||||||||||||||||||
Temperature | Centigrade | 135± 3 | 100± 2 | ||||||||||||||||
Duration | h | 168 | 168 | ||||||||||||||||
Max. rate of change of tensile strength | % | ± 25 | |||||||||||||||||
Min. tensile strength | N/mm 2 | 9 | |||||||||||||||||
Max. rate of change of elongation at break | % | ± 20 | |||||||||||||||||
Min. elongation at break | % | 110 | |||||||||||||||||
Test for thermal extension | |||||||||||||||||||
Air temperature | Centigrade | 200± 3 | |||||||||||||||||
Loading time | Min | 15 | |||||||||||||||||
Mechanical tensile force | N/mm 2 | 0.2 | |||||||||||||||||
Max. elongation when loading | % | 175 | |||||||||||||||||
Maximum permanent deformation after cool | % | 15 | |||||||||||||||||
Water absorption test (weight method) | |||||||||||||||||||
Temperature | Centigrade | 85± 2 | 85± 2 | ||||||||||||||||
Duration | d | 14 | 14 | ||||||||||||||||
Maximum weight change | mg/cm 2 | 1 | 25 | ||||||||||||||||
Shrinkage test | |||||||||||||||||||
Temperature | Centigrade | 130 | |||||||||||||||||
Duration | h | 1 | |||||||||||||||||
Maximum permitted shrinkage rate | % | 4 | |||||||||||||||||
Weight-loss test in oven | |||||||||||||||||||
Temperature | Centigrade | 100± 2 | |||||||||||||||||
Duration | h | 168 | |||||||||||||||||
Maximum permitted weight-loss | mg/cm 2 | 0.5 | |||||||||||||||||
Nominal Cross sectional area of conductor mm 2 | Max. D. C. resistance of conductor at 20 Centigrade | ||||||||||||||||||
Copper | Aluminum | ||||||||||||||||||
1.5 | 12.1 | — | |||||||||||||||||
2.5 | 7.41 | 12.1 | |||||||||||||||||
4 | 4.61 | 7.41 | |||||||||||||||||
6 | 3.08 | 4.61 | |||||||||||||||||
10 | 1.83 | 3.08 | |||||||||||||||||
16 | 1.15 | 1.91 | |||||||||||||||||
25 | 0.727 | 1.20 | |||||||||||||||||
35 | 0.524 | 0.868 | |||||||||||||||||
50 | 0.387 | 0.641 | |||||||||||||||||
70 | 0.268 | 0.443 | |||||||||||||||||
95 | 0.193 | 0.320 | |||||||||||||||||
120 | 0.153 | 0.253 | |||||||||||||||||
150 | 0.124 | 0.206 | |||||||||||||||||
185 | 0.0991 | 0.164 | |||||||||||||||||
240 | 0.0754 | 0.125 | |||||||||||||||||
300 | 0.0601 | 0.100 | |||||||||||||||||
400 | 0.0470 | 0.0778 | |||||||||||||||||
500 | 0.0366 | 0.0605 | |||||||||||||||||
630 | 0.0283 | 0.0469 | |||||||||||||||||
800 | 0.0221 | 0.0367 | |||||||||||||||||
1000 | 0.0176 | 0.0291 |