-50~750C laser Infrared thermometer with data logging TL-IR750 Quality Choice
USD $6 - $12 /Piece
Min.Order:10 Pieces
Dongguan Xinrui Instrument Co., Ltd.
hot sale data logging infrared thermometer -50~550C with laser point factory lowest price TL-IR550
IR infrared digital temperature thermometer,car thermometer in out
High quality pocket digital infrared thermometer for home and industrial factory price TL-IR750
For home and industrial Plastic infrared thermometer factory price TL-IR750
2016 data logging Digital Infrared Temperature Temp Gun Thermometer Non-Contact IR Laser Point TL-IR750
Advantage:
A: Room temperature measurement function
B:Data logging (30+) and Data Hold function
C:Emissivity adjustable
D:Bar graph display.
E:Package: colorbox with black bag
This infrared thermometer is used for measuring the temperature of the object's surface, which is applicable for various hot, hazardous or hard-toreach objects without contact safely and quickly.
This unit consist of Optics, Temperature Sensor Signal amplifier,Processing circuit and LCD Display. The Optics collected the infrared energy emitted by object and focus onto the Sensor. Then the sensor
translates the energy into an electricity signal.
This signal will be turned out to be digital shown on the LCD after the signal amplifier and processing circuit.
Features:
1 Large Measurement Range
2 Laser On/Off Switch Function
3 LCD with White Backlight and Bar Graph Display
4 Celsius and Fahrenheit Switchable
5 High/Low Temperature Alarm Setting
6 Auto Power Off
7 Data Recording (30 Max) and Data Hold Function
8 Emissivity Adjustable
9 Room Temperature Measurement
10 MAX/MIN/AVG/DIF Reading Function
11 Low Battery Indicator
12 Stylish Mini Handheld Gun Design
Specifications:
Temperature Range: -50 to 750oC
Accuracy: ±1.5% or ±1.5oC
Resolution: 0.1oC or 0.1F
Repeatability: 1% of reading or 1oC
Response Time: 500mSec, 95% Response
Spectral Response: 8-14 um
Emissivity: 0.95 Preset (Adjustable)
Distance to Spot Size: 12:1
Operation Temperature: 0 to 50oC (32 to 122oF)
Operation Humidity: 10 to 90%RH
Storage Temperature: -10 to 60oC (14 to 140oF)
Storage Humidity: 10 to 75%RH
Size: 145*90*35mm
Weight: 120g (including average 9V battery)
Product description:
1.Laser output
2.Measuring button
3.LCD display
4.Product label
5.Rec button
6.Mode button
7.Laser/Backlight button
8.Max/Min/Avg/Dif button(↑)
9.oC/oF button(↓)
10.Battery cover
LCD display
1.Measuring indicator
2.HOLD symbol
3.Buzzer alarm symbol
4.Laser switch indicator
5.Low battery indicator
6.Low temperature limit alarm
7.High temperature limit alarm
8.Bargraph
9.Temperature units:oC,oF
10.Digtal readout
11.MaxMin/Avg/Dif reading mode incicator
12.Data recording display(Max 30 datas)
13.Emissivity(adjustable)
14.Room temperature measurement reading
Field of View
This infrared thermometer’s field of view is 12:1, meaning that if the meter is 12 inches from the target, the diameter of the object under test must be at least 1 inch. Other distances are shown below in the field of view diagram.
Operation:
1.Turning on and off your Meter
Press the Measuring button to turn on the meter,
The meter will auto power off after 7sec with any operation
2.Hold function
This instrument automatically enter hold mode without measuring
Under hold mode, current reading display will be freezed.
3.MAX/Min/Avg value measurement function
11.Press Max/Min/Avgbutton(↑) to choose Max reading,Min reading,Avg reading display mode
Max: When is this mode the meter will display the maximum value has reached
Min: When is this mode the meter will display the minimum value has reached
AVG: When is this mode the meter will display the average value has reached
DIF:When is this mode the meter will display the differential value of maximum value and minmum value has reached
4.Laser and Backlight function
a.Press Laser/Backlight button to turn on/off laser.
b.Press this button over 2sec to turn of/off backlight
5.Temperature units switch function
Press oC/oF button(↓) to switch the temperature units between Celsius and Fahrenheit
6.Datas recording function
Press Rec button to manual store any measuring datas (Max 30 datas).
7.Datas recall function
Press Rec button over 2sec to recall datas
*oC/oF button(↓); Max/Min/Avg button(↑)
8.Low and High temperature limit alarm setup
Press Mode button over 2sec to adjust alarm temperature
*Mode button(→);oC/oF button(↓) ; Max/Min/Avg button(↑)
9.Emissivity adjustable
Under Scan mode:press oC/oF button(↓) and Max/Min/Avg button(↑) to adjust the emissivity
Most (90% of typical applications) organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cove the surface to be measured with masking tape or flat black paint. Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature of the tape or painted surface.
Emissivity Values
Substance | Thermal emissivity | Substance | Thermal emissivity |
Asphalt | 0.90 to 0.98 | Cloth (black) | 0.98 |
Concrete | 0.94 | Human skin | 0.98 |
Cement | 0.96 | Lather | 0.75 to 0.80 |
Sand | 0.90 | Charcoal (powder) | 0.96 |
Earth | 0.92 to 0.96 | Lacquer | 0.80 to 0.95 |
Water | 0.92 to 0.96 | Lacquer (matt) | 0.97 |
Ice | 0.96 to 0.98 | Rubber (black) | 0.94 |
Snow | 0.83 | Plastic | 0.85 to 0.95 |
Glass | 0.90 to 0.95 | Timber | 0.90 |
Ceramic | 0.90 to 0.94 | Paper | 0.70 to 0.94 |
Marble | 0.94 | Chromium oxides | 0.81 |
Plaster | 0.80 to 0.90 | Copper oxides | 0.78 |
Mortar | 0.89 to 0.91 | Iron oxides | 0.78 to 0.82 |
Brick | 0.93 to 0.96 | Textiles | 0.90 |
SAFETY
1.Use extreme caution when the laser beam is turned on.
2.Do not let the beam enter your eye, another person’s eye or the eye of an animal.
3.Be careful no to let the beam on a reflective surface strike your eye.
4.Do not allow the laser light beam impinge on any gas which can explode.
Battery Replacement:
If the meter does not power on as usual or the low battery icon appears on the LCD display, please replace the batteries with a new 9V battery as soon as possible. The way to open the battery cover see below operation:
Dispose of the battery in an environmentally safe at a recycling point.
DO NOT DISPOSE OF IN YOUR BIN!
Trouble Shooting:
1. Power on but no display or the display disappears
a. Check the battery is in place with good contact to the pins and the correct way round.
b. Remove battery for one minute and re-install.
c. Replace the battery.
2. For all other issues please contact your supplier.
Our services:
1.Sample order/Mix order is available;
2.Sample charge is refundable !
3.If order quantity is big , we will provide you most competitive price !
4.OEM and ODM service is available.
5.Cheapest shipping cost could be provided!