Product Details

Cheap spectrophotometer

Place of Origin Jiangsu, China
Brand Name JIEBO
Model Number AA4530F
Wavelength Range 190~900nm
Measurement Range ppm

Product Features

 

Product Description

 

CHARACTERISTICS

1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.

3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize

the working condition of the hollow cathode lamp.

4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.

5. Fully automated wavelength scanning and peak searching.

6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.

7. Deuterium lamp and self-absorption background regulation.

8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.

9. Measuring method: flame absorption method and emission method.

10.Result printing: parameter printing, data result printing and diagram printing.

 

COMPLETE AUTOMATIC CONTROLLING SYSTEM

With the help of the software, the following can be easily achieved

1. Selection of the element lamp

2. Up-down-front-rear adjustment of the lifter

3. Adjustment of the optical energy

4. Selection of the slit

5. Determination of wavelength scanning and peak searching

6. Selection of the atomizer

7. Setting of the background deduction method

8. Controlling of the gas flow

9. Automatic flaming and flaming out

10.Setting of the graphite furnace testing method

 

ADVANCED GRAPHITE FURNACE TEMPERA- TURE CONTROLLING TECHNOLOGY

The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data

The fast heating capacity can improve the flexibility of the elements further

Use the ordinary power source of 220V without

need of dynamic power of 380V

The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples

Three grades adjustable gas flow can accustom to more application needs

Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error

 

SAFE, RELIABLE AND CONVENIENT FLAME SYSTEM

EPC can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily

Efficient atomization system enables a higher

sensitivity

The whole operation system has a high security as the fire safety system can alarm whenever the electrici- ty is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit temper ing. Thus it keeps the operation people and equipment from harm and damage.

 

MULTI-FUNCTIONAL SOFTWARE WORKSTATION

A workstation that is supported WINDOWS XP/2000/NT

The rich menu brings great convenience to the use of customer

Convenient conversion between different menus makes the operation more easily

Various analytical correction methods provide the users more choices

Basic default parameter settings enable even the beginners can do the normal operation

Flexible storage, editing and printing me thods give the user largest support

 

Technical Parameters

SPECIFICATIONS

 

Wavelength range Spectral bandwidth

Accuracy of the wavelength

Receptivity of the wavelength Base line stability Characteristic viscosity Checking limit

Preciseness Grating Inflamer Atomizer Lamp stand

 

D2 background correction ability

 

Size and weight

Power source

 

 

190 – 900nm

0.1, 0.2, 0.4, 1.0 and 2.0nm

±0.15nm

≤0.04nm

≤0.002A/30min (Cu)

0.02μg/ml/1% (Cu)

0.004μg/ml (Cu)

0.5%

1800 lines/mm

All-metal titanium burner

Effective glass atomizer

8

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

700mm×550mm×450mm 75Kg

220V±22V AC

 

FLAME SYSTEM

Acetylene air burner

Ignition dynamic baseline drift

(Cu) Characteristic viscosity

Related standard deviation of the accuracy

 

Safety system

 

 

100mm

≤0.006A/30min

≤0.025μg/ml/1%

≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

 

 

 

 

GRAPHITE FURNACE

The highest temperature

The largest temperature rising speed

Characteristic quantity

Accuracy

Size and weight

 

Safety system

 

3000℃

≥2000℃/S

Cd≤0.5×10-12g Cu≤0.5×10-11g

Cu≤3% Cd≤3%

550mm×450mm×300mm 65Kg

Over current protection Low air pressure alarm / protection

Low cooling water flow alarm/protection

 

Power source and power 220V±22V AC 7000W

 

 

Packaging & Shipping

 

STANDARD ACCESSORIES

 

PC workstation

HP inkjet printer

Oil free Air compressor

Acetylene reducing valve

Cu Hollow cathode lamp

Cheap spectrophotometerAir filter

 

Our Services

 Cheap spectrophotometer

 

Certificates

 

 

Factory Overview

 

 

Contact Information

 Cheap spectrophotometer

 

 

 

 

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now