120W 12V switch power supply with ups function monitor (SC-120W)
Negotiable /Piece
Min.Order:500 Pieces
Zhejiang Carspa New Energy Co., Ltd.
120W 12V switch power supply with ups function monitor (SC-120W)
UPS function monitor power supply 120W
Features:
·Universal AC input
·Small volume,low weight, high efficiency
·Protections: short circuit/over load
·Indicator for power on/charge/normal(LED)
·100% full load burn-in test
·Battery protection at low voltage
·2 Year warranty
Model | SC-120-12 | SC-120-24 | |||
Output | DC voltage | CH1:13.8V | CH1:13.4V | CH1:27.6V | CH2:26.5V |
Voltage tolerance | ±1% | ----- | ±1% | ----- | |
Rated current | 8A | 0.5A | 4A | 0.3A | |
Current range | 0~8A | ----- | 0~4A | ----- | |
Rated power | 117.1W | 118.4W | |||
Ripple&noise | 120mvp-p | ----- | 180mvp-p | ----- | |
DCvoltage ADJ.range | CH1:11.3~14.9V | CH1:21.3~29.8V | |||
Input | Voltage range | 90~264VAC,127~370VDC | |||
Frequency | 47~63Hz | ||||
AC current | 2.8A/115VAC, 1.4A/230VAC | ||||
Efficiency | 81% | 83% | |||
Inrush current | cold start current 30A/115VAC, 50A/230VAC | ||||
Leakage current | < 1mA/240VAC | ||||
Protection | Over load | above 110%~150% rated power | |||
protection mode: AC charging mode:hiccup mode auto-recovery after fault condition is removed | |||||
Battery protection at low voltage | 9.5~11V | 20~22V | |||
protection mode: cutoff output | |||||
Function | UPS introduction | long-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop harging when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch,no switch time,no need human guard | |||
cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs | |||||
Environment | Working temp,humidity | -10°C~+60°C, 20%~90%RH | |||
Storagetemp,humidity | -20°C~+85°C, 10%~95%RH non-condensing | ||||
Withstand vibration | 10~500Hz, 2G 10min/1cycle, period for 60 minutes,each axes | ||||
Safety | Withstand voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG: 100M ohms/500VDC | ||||
Fitstandard | Safety standard | compliance to UL60950-1 | |||
EMC standard | compliance to EN55022,CLASSB | ||||
Others | Dimension | 159*97*38mm (L*W*H) | |||
Weight/packing | 0.56kg/45pcs/26kg/0.041m³/1.45CUFT | ||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||
3. Tolerance: includes set up tolerance, line regulation and load regulation. |