200W HLG series Full function adjustable waterproof power supply
Negotiable /Piece
Min.Order:500 Pieces
Zhejiang Carspa New Energy Co., Ltd.
150W HLG series Full function adjustable waterproof power supply
100W HLG series Full function adjustable waterproof power supply
120W HLG series Full function adjustable waterproof power supply
80W HLG series Full function adjustable waterproof power supply
60W HLG series Full function adjustable waterproof power supply
Full function adjustable waterproof power supply 200W
Features:
·Universal AC input
·Built-in power factor correction
·Protections: short circuit/over load/over voltage/over temp
·Cooling by free air convection
·OCP point adjustable through output cable or internal potentiometer
·IP67/65 design for indoor or outdoor installations
·Suitble for LED lighting and moving sign applications
·3Year warranty
Specifications:
Model | HLG-200-12 | HLG-200-20 | HLG-200-24 | HLG-200-36 | HLG-200-48 | |
OUTPUT | DC voltage | 12V | 20V | 24V | 36V | 48V |
Constant current region | 6~12V | 10~20V | 12~24V | 18~36V | 24~48V | |
Rated current | 14A | 10A | 8.4A | 5.6A | 4.2A | |
Rated power | 168W | 200W | 201.6W | 201.6W | 201.6W | |
Ripple & noise | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | 200mvp-p | |
Voltage ADJ range | 10.8~13.5V | 17~22V | 22~27V | 33~40V | 43~53V | |
Current ADJ range | can be adjusted by internal potentiometer or through output cable | |||||
7~14A | 5~10A | 4.2~8.4A | 2.8~5.6A | 2.1~4.2A | ||
INPUT | Voltage range | 90~264VAC, 47~63Hz, 127~370VDC | ||||
AC current | 2.0A/115VAC,1.1A/230VAC | |||||
Power factor | PF>0.95/230VAC, PF>0.98/115VAC(full load) | |||||
Efficiency | 92% | 93% | 94% | 94% | 94% | |
Inrush current | cold start current 35A/115VAC,75A/230VAC | |||||
Leakage current | <0.75mA/240VAC | |||||
PROTECTION | Over current | 95%~108% | ||||
protection type: constant current limiting, auto-recovery after fault condition is removed | ||||||
Short circuit | Hiccup mode, recovers automatically after fault condition is remove | |||||
Over voltage | 14~17V | 23~27V | 28~34V | 41~46V | 54~60V | |
protection type: Shut down o/p voltage re-power on to recover | ||||||
Over temperature | 100°C±10°C(RTH2) | |||||
protection type: Shut down o/p voltage re-power on to recover | ||||||
ENVIRONMENT | Working temp, humidity | -20°C~+60°C,20%~90%RH | ||||
Storage temp, humidity | -40°C~+85°C, 10%~95%RH non-condensing | |||||
Withstand vibration | 10~500Hz, 2G 10min/1cycle, period for 60 minutes, each axes | |||||
SAFETY | Withstand voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG: 100M ohms/500VDC | |||||
FIT STANDARDS | Safety standard | Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved | ||||
EMC standard | Fit EN55015, EN61000-3-2 Class C(>60%load):EN61000-3-3 | |||||
OTHER | Dimension | 247*69*39mm (L*W*H) | ||||
Weight/packing | 1.3kg/20pcs/27kg/0.033m³/1.07CUFT | |||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||