120W HLG series Full function adjustable waterproof power supply
Negotiable /Piece
Min.Order:500 Pieces
Zhejiang Carspa New Energy Co., Ltd.
Full function adjustable waterproof power supply 120W
Features:
·Universal AC input
·Built-in power factor correction
·Protections: short circuit/over load/over voltage/over temp
·Cooling by free air convection
·OCP point adjustable through output cable or internal potentiometer
·IP67/65 design for indoor or outdoor installations
·Suitble for LED lighting and moving sign applications
·3Year warranty
Specifications:
Model | HLG-120-12 | HLG-120-20 | HLG-120-24 | HLG-120-36 | HLG-120-48 | |
OUTPUT | DC voltage | 12V | 20V | 24V | 36V | 48V |
Constant current region | 6~12V | 10~20V | 12~24V | 18~36V | 24~48V | |
Rated current | 10A | 6A | 5A | 3.4A | 2.5A | |
Rated power | 120W | 120W | 120W | 122.4W | 120W | |
Ripple & noise | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | 200mvp-p | |
Voltage ADJ range | 10.8~13.5V | 17~22V | 22~27V | 33~40V | 43~53V | |
Current ADJ range | can be adjusted by internal potentiometer or through output cable | |||||
5~10A | 3~6A | 2.5~5A | 1.7~3.4A | 1.2~2.5A | ||
INPUT | Voltage range | 90~264VAC, 47~63Hz,127~370VDC | ||||
AC current | 1.4A/115VAC, 0.6A/230VAC | |||||
Power factor | PF>0.95/230VAC, PF>0.98/115VAC(full load) | |||||
Efficiency | 90% | 93% | 93% | 93% | 93% | |
Inrush current | cold start current 35A/115VAC, 75A/230VAC | |||||
Leakage current | <0.75mA/240VAC | |||||
PROTECTION | Over current | 95%~108% | ||||
protection type: Constant current limiting, auto-recovery after fault condition is removed | ||||||
Short circuit | Hiccup mode, recovers automatically after fault condition is remove | |||||
Over voltage | 14~17V | 23~27V | 28~34V | 41~46V | 54~60V | |
protection type: Shut down o/p voltage re-power on to recover | ||||||
Over temperature | 100°C±10°C(RTH2) | |||||
protection type: Shut down o/p voltage re-power on to recover | ||||||
ENVIRONMENT | Working temp, humidity | -20°C~+60°C, 20%~90%RH | ||||
Storage temp, humidity | -40°C~+85°C, 10%~95%RH non-condensing | |||||
Withstand vibration | 10~500Hz, 2G 10min/1cycle, period for 60 minutes, each axes | |||||
SAFETY | Withstand voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG: 100M ohms/500VDC | |||||
FIT STANDARD | Safety standard | Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved | ||||
EMC standard | Fit EN55015, EN61000-3-2 Class C(>60%load):EN61000-3-3 | |||||
OTHER | Dimension | 223*69*39mm (L*W*H) | ||||
Weight/packing | 1kg/20pcs/21kg/0.03m³/1.07CUFT | |||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||
3. Tolerance: includes set up tolerance, line regulation and load regulation. |