Dual output ac/dc power supply D60 24V
USD $1 - $100 /Piece
Min.Order:50 Pieces
Zhejiang Huajing Rectifier Co., Ltd.
105°C Output capacitor
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effect
With short-circuit and overload protection
100% full-load burn-in test
Installed with EMI filter, minimum wave
Model Performance | D-60A | D-60B | ||
CH1 | CH2 | CH1 | CH2 | |
DC output voltage | 5V | 12V | 5V | 24V |
Output Voltage Tolerance (Note 2) | ±2% | ± 6% | ±2% | ±5% |
Rated output current | 4A | 3A | 3A | 1.8A |
Output Current Range | 0.3-6A | 0.2-4A | 0.3-6A | 0.2 -2.2A |
Ripple and noise (Note 3) | 75mVp-p | 150mVp-p | 75mVp-p | 150mVp-p |
Into the line of stability (Note 4) | ± 0.5% | ± 1% | ± 0.5% | ± 0.5% |
Load stability (Note 5) | ± 0.5% | ± 4% | ± 0.5% | ± 4% |
DC output power | 56W | 58W | ||
Efficiency | 73% | 76% | ||
DC voltage adjustable range | CH1:+10, -5% | CH1:+10, -5% | ||
Input Voltage Range | 85 ~ 264VAC 47 ~ 63Hz | |||
Input Current | 2A /115V,1A/230V | |||
Inrush Current | Current 30A/115V 60A/230V cold start | |||
Leakage | <1A /240VAC | |||
Overload | 105% ~ 150% Type: PULSING HICCUP SHUTDOWN RESET: Automatic recovery |