triple output switching power supply T30
USD $1 - $100 /Piece
Min.Order:50 Pieces
Zhejiang Huajing Rectifier Co., Ltd.
105°C Output capacitor
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effect
With short-circuit and overload protection
100% full-load burn-in test
Installed with EMI filter, minimum wave
Model Performance | T-30A | T-30B | ||||
CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC output voltage | 5V | 12V | -5V | 5V | 12V | -12V |
Output Voltage Tolerance (Note 2) | ±2% | +2,-6% | +2,10% | ± 2% | +2,-6% | ±6% |
Rated output current | 3A | 1A | 0.5A | 3A | 1A | 0.5A |
Output Current Range | 0.5 -3A | 0.1-1A | 0.1 -0.5A | 0.5 -3A | 0.1-1A | 0.1 -0.5A |
Ripple and noise (Note 3) | 50mVp-p | 100mVp-p | 50mVp-p | 50mVp-p | 100mVp-p | 100mVp-p |
Into the line of stability (Note 4) | ±0.5% | ±1% | ± 1% | ± 0.5% | ± 1% | ± 1% |
Load stability (Note 5) | ±0.5% | ±5% | ± 5% | ± 0.5% | ± 0.5% | ± 0.5% |
DC output power | 30W | 33W | ||||
Efficiency | 70% | 72% | ||||
DC voltage adjustable range | CH1:+10,-5% | CH1:+10,-5% | ||||
Input Voltage Range | 85 ~ 132VAC/170 ~ 264VAC by switch 47 ~ 63Hz | |||||
Input Current | 0.8A /115V,0.45A /230V | |||||
Inrush Current | Current 18A/115V 36A/230V cold start | |||||
Leakage | < 0.5A /240VAC / | |||||
Overload | 105% ~ 150% Type: FOLDBACK cut output reset: Automatic restore |