SAT-1CS 2M Transmission Analyzers, also called E1 BER Tester , is mainly used for measuring of the error rate of data communication and for the analysis of line fault and causes, and very suitable for the parameter measurement and routine maintenance testing of 2M system, N×64K communication channels.SAT-1CS 2M Transmission Analyzers can be used to test the digital channels with 2Mbit/s interfaces and with V.24/V.28/RS232, V.35, V.36, RS449, X.21, RS485, EIA530, EIA530A, and equidirectional 64kbit/s interfaces.
For Datacom:
V.24/RS232/V.28, V.35, V.36, X.21, RS-449, RS-485, RS422, EIA-530, EIA-530A datacom testing SYNCH and ASYNCH testing DTE and DCE emulation Bit code testing Pattern slip testing Signal loss alarm Line signal level and frequency testing Loop delay testingAutomatic protection switching time testing(APS) G.821, M2100 service interrupt error testing
For co-directional 64Kbit/s:
Service interrupt error testing Bit code testing Pattern slip testing Signal loss AIS alarm Line signal frequency testing Loop delay testing Automatic protection switching time testing(APS) G.821, M.2100 error testing
Technical Index 2M Technical Index
(1) Signal input rate: 2048kbit/s±100ppmG.703 requirement±50PPM
(2) Signal coding: HDB3, AMI.
(3) Input jitter tolerance: Up to the requirement of Figure 10.1.
(4) Input balance response: Attenuation complies with the law of square root of frequency, and is within the range of 0 to 6dB at 1024 kHz.
(5) Input Impedance
(5.1) Unbalance terminating: 75Ω ,Balance terminating: 120Ω.Reflection loss >18dB within 50Hz3100kHz.
(5.2) Unbalance bridging: >750Ω,Balance bridging: >1200Ω
(5.3) Unbalance monitoring: 75Ω, 26dB gain,Balance monitoring: 120Ω, 26dB gain
Reflection loss >18dB within 50Hz3100kHz.
(6) Signal structure
(6.1) Non-frame structure
(6.2) Frame structure: PCM30, PCM31, PCM30CRC, PCM31CRC,Frame structure complies with the requirement of G. 704.
(7) Testing pattern: 26-129-1211-1215-1220-1223-1, and artificial code
(8) Impedance of output interface:
(8.1) Non-balance 75Ω, up to G. 703
(8.2) Balance 120Ω, up to G. 703.
(9) External clock input
(9.1) Signal form: HDB3, NRZ
(9.2) Balance terminating resistance: 120ΩUnbalance terminating resistance: 75Ω.
Balance bridging resistance: >1200Ω Unbalance bridging resistance: >750Ω.
(10) Error code insertion: None, single, or ratio 10-1 ~ 10-7.
Co-directional 64k Technical Index
(1) Signal input rate: 64 kbit/s±100ppmG.703 requirement±100PPM
(2) Input impedance: Balance 120Ω, up to G.703
(3) Input jitter tolerance: Up to G.823.
(4) Impedance of output interface: Balance 120Ω, up to G.703
(5) Testing pattern:26-129-1211-1215-1220-1223-1, and artificial code
Input Impedance
Datacom Inde
(1) Data interface type: V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530 and EIA-530A.
(2) Generator
(2.1) SYNCH mode
Clock source: Internal or external clock
Phase relation between clock and data: co-direction or reverse direction.
Rate: 1.2,2.4,4.8,9.6,14.4,19.2,38.4,48,56(kbps)N×64kbpsN=132
Error: ±15ppmppm: parts per million
(2.2) ASYNCH mode
Rate: 50,75,110,150,200,300,600,1200,2400,3600,4800,7200,960014.4k,19.2k,38.4k,57.6kbps
Data structure: Word length: 5,6,7,8bitsStop bit: 1,2bits
Odd-even check: odd, even, 1, 0, none
(2.3) Error code insertion: None, single, or ratio 10-1 ~ 10-7.
(3) Receiver
(3.1) SYNCH mode
Clock source: Internal or external clock
Phase relation between receive clock and receive data: Equidirection or reverse direction.
Clock Rate: 2048kbps at a maximum
(3.2) ASYNCH mode
The rate and data are the same as those of the generator.
(4) Testing pattern: 26-129-1211-1215-1220-1223-1, and artificial code
Other Parameters
Power supply
(1) Special power adapter;Input: AC220V 50Hz,Output: DC 9V 1A
(2) Internal rechargeable battery
4000mAh, 6V nickel-hydrogen rechargeable battery
Working time: 8 hours
Charging: 8 hours at power-off state, and 12 hours at power-on state.
Dimension and weight;L×W×H: 200×160×42mm;Weight: 950g
Ambient parameters
Operation temperature: 040
Storage Temperature: -30+70
Humidity: 5%90%, non-condensing
Standard Configuration
No. | Item | Qty |
1 | SAT-1CS Series 2M Transmission Analyzers | 1 set |
Attached files | ||
2 | User's manual | 1 pc |
3 | Software disc | 1 pc |
Attached accessories | ||
4 | 75Ω Coaxial testing line | 1 pc |
5 | BNC-L9 Testing line CESHIYI | 2 pcs |
6 | RS232 serial line | 1 pc |
7 | Special testing cable of data communicationV.24,RS-485,EIA-530,EIA-530A | 1 pc |
8 | Special testing cable of data communicationRS-449,V.36 | 1 pc |
9 | Special testing cable of data communication X.21 | 1 pc |
10 | Special testing cable of data communication V.35 | 1 pc |
11 | G.703 CO special testing cable64Kb/s coaxial interface | 1 pc |
12 | Power adapter | 1 pc |
13 | Data self-loop head | 1 pc |
14 | Switch cable | 1 pc |
15 | Handy-case | 1 pc |
16 | Serial printing lineoptional | 1 pc |