4 pole soil resistivity Earth Resistance Tester
Negotiable /Set
Min.Order:1 Set
Shaanxi Aitelong Technology Co., Ltd.
SAT-10C Earth Tester is latest digital precision earth resistance tester of our company, it is with these functions below:
Features:
1. When measuring by 2-pole, there is no need digging the auxiliary rod, the test is simple and fast.
2. It could measure earth resistance and soil resistivity by 3-pole and 4-pole; also it could measure AC voltage.
3. It should display noise during test and signal when a battery is replaced
4. It should display signal when it exceeds test range.
5. The instrument would automatically stop the measurement when performing misoperation,
6. International standard: ISO9001:2000
Test item:
Earth resistance Re by 2-pole, 3-pole and 4-pole
Re range(Ω) | Resolution(Ω) | Accuracy |
0~19.99 | 0.01 | ±(2%+2d) |
20~199.9 | 0.1 | ±(2%+2d) |
200~1999 | 1 | ±(2%+2d) |
Soil resistivity ρ measurement
ρ range(Ω) | Resolution(Ω) | Accuracy |
0~19.99 | 0.01 | ±(2%+2d) |
20~199.9 | 0.1 | ±(2%+2d) |
200~1999 | 1 | ±(2%+2d) |
2.00K~19.99K | 10 | ±(2%+2d) |
20.0K~125.6K | 100 | ±(2%+2d) |
AC voltage measurement
Range (V) | Resolution(V) | Accuracy |
0~400 | 1 | ±(2%+2d) |
Technical parameters:
Resistance measurement range | 0~2000Ω |
Resolution | 0.01Ω |
Accuracy | ±(2%+2d) |
Voltage measurement | <80V,sine wave |
Current measurement | ≤10 mA |
Frequency measurement | 125Hz±1Hz |
Measurement result | average value of 2 times or 5 times |
the max solving resistance of testing line | 5Ω |
LCD dimension | 3.5 bits,height of character: 19mm |
Memory capacity | 15 data |
Voltage measurement range | 0~400V,resolution: 1V |
Insulation intensity test | 2500V |
Power supply | 4×1.5V AA alkaline battery |
Max dimensions | 260(L)×145(W)×60(H)mm |
Weight | 1kg (about 3kg with accessories) |
Safety and environment condition | IP54.; IEC10101-1; EMC 50081-1, 50082-1 or IEC 61326-1 |
Working temperature and humidity | -10°C~ 50°C, RH 90% |
Custody temperature and humidity | -20~60°C, RH 90 |