China supplier easy to use generator load bank tester
Negotiable /Set
Min.Order:1 Set
Shaanxi Aitelong Technology Co., Ltd.
China supplier easy to use generator dummy load ups power testing
China supplier stationary lead acid battery electronic dummy load
China supplier stationary lead acid battery capacity tester with dc load meter
China supplier stationary lead acid battery capacity analyzer and tester
China supplier stationary battery dc dummy load for testing battery
SAT-ACO380 AC load is generator load bank tester
Functions & Features
-Test discharge three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time, energies of generators and UPS.
-Set/adjust discharging power according to performance parameters and detection requirements
-Set discharging time, timing to automatic shut-off load, discharge off and alarm operator
-Set over/under voltage protection threshold value, it can shut off load, terminate discharging and alarm user automatically.
-Large LCD screen, friendly interface. English menu and easy operation.
-Parallel operation function to carry out multi sets load operation by RS 485 communication
-Built-in storage function, save 30 groups of test data, which can be inquired, deleted and put into SD card.
-Start/stop discharging control by Serial port, and detect data real time operation etc; The storage data can be uploaded to PC by serial port or SD card, and the upper computer’s software can analyze data and pattern and print report etc.
-Overheating and over current protection function, it can turn off load, terminate discharging and alarm automatically when over temperature and over current.
-Set at most 5 groups power, load process automatically according to the setting power and operation time after being turned on.
Mode | ACO 380/02 | ACO 380/04 | ACO 380/10 | |||
Working environment | Working Temperature: (-20~55)℃ Storage Temperature: (-45~75)℃ Relative humidity: 90%(40±2℃) Atmospheric pressure: (70~106)KPa | |||||
Working power supply | Single-phase AC220V±10, 50Hz | |||||
Load voltage | Three-phase AC380V, Single-phase AC220V | |||||
Operating power | Stand-alone: Max 20KW (Three-phase 380V) Max 6KW (Singly-phase 220V) | Stand-alone: Max 40KW (Three-phase 380V) Max 13KW (Singly-phase 220V) | Stand-alone: Max 100KW (Three-phase 380V) Max 30KW (Singly-phase 220V) | |||
Cooling mode | FCT(Fan control Temperature) | |||||
Communication Mode | RS232, RS485 and SD card | |||||
Display mode | 8 inch TFT | |||||
Voltage measurement range | AC 0~450V, Display Resolution: 0.1V, Precision: ±0.5% | |||||
Current measurement range | AC 0~100A, Display Resolution: 0.1A, Precision: ±0.5% | AC 0~150A, Display Resolution: 0.1A, Precision: ±0.5% | AC 0~300A, Display Resolution: 0.1A, Precision: ±0.5% | |||
Frequency measurement range | 40~60 Hz, Display Resolution: 0.01Hz, Precision: ±0.2% | |||||
Power measurement range | 0~20 KVA, Display Resolution: 0.1KVA, Precision: ±1% | 0~40 KVA, Display Resolution: 0.1KVA, Precision: ±1% | 0~100 KVA, Display Resolution: 0.1KVA, Precision: ±1% | |||
Power factor measurement range | 0.001~1.000, Display Resolution: 0.001, Precision: ±0.5% | |||||
Discharging Time | (0~19 hours and 59 minutes) adjustable continuously | |||||
Quantity of Parallel operation | 1~99 sets | |||||
Recording Period | 6~999 Seconds | |||||
Temperature measurement range | -20~100℃,Display resolution: 1℃, precision:±1℃ | |||||
Insulating strength | Input≥AC1500V Output≥AC500V | |||||
MTTF | ≥50000h | |||||
Dimensions(mm) | 420×500×750mm | 680×600×900mm | 680×600×900mm | |||
Weight | 30kg | 50kg | 70kg |