inverter for ups use
USD $100 - $1,000 /Piece
Min.Order:1 Piece
Foshan Baykee New Energy Technology Incorporated Company
Quiet, high efficient
Can connect battery
Humanization panels display
High overload capacity
Backup power supply with quick switch
Three-stage charging
30A/60A automatic three-stage battery charger
Model NS Series | Model ( NS Series ) | |||||||
1012 | 1024 | 2012 | 2024 | 3024 | 3048 | 5048 | 6048 | |
1000W | 1000W | 2000W | 2000W | 3000W | 3000W | 5000W | 6000W | |
12Vdc | 24Vdc | 12Vdc | 24Vdc | 24Vdc | 48Vdc | 48Vdc | 48Vdc | |
Utility pattern specification | ||||||||
Input Wave Form | Sine wave (Utility or generator) | |||||||
Nominal Voltage | 100VAC/110VAC/120VAC or 220VAC/230VAC/240VAC | |||||||
Low Voltage Trip | 90VAC±4% or 184VAC±4% | |||||||
Low Voltage Reengage | 100VAC±4% or 194VAC ±4% | |||||||
High Voltage Trip | 140VAC±4% or 253VAC±4% | |||||||
High Voltage Reengage | 135VAC±4% or 243VAC±4% | |||||||
Max. AC Input Voltage | 150VAC or 270VAC | |||||||
Nominal Input Frequency | 50Hz/ 60Hz ( Auto detect ) | |||||||
Low Frequency Reengage | 58+0.3Hz for 60Hz, 48+0.3Hz for 50Hz | |||||||
Low Frequency Trip | 57+0.3Hz for 60Hz,47+0.3Hz for 50Hz | |||||||
High Frequency Reengage | 64+0.3Hz for 60Hz, 54+0.3Hz for 50Hz | |||||||
High Frequency Trip | 65+0.3Hz for 60Hz,55+0.3Hz for 50Hz | |||||||
Output Wave Form | Bypass mode, same as input | |||||||
Overload Protection | Circuit Breaker | |||||||
Short Circuit | Circuit Breaker | |||||||
Efficiency | >95% | |||||||
Transfer Switch Current | 30A | |||||||
Transfer Time (Ac to Dc) | 10ms | |||||||
Transfer Time (Dc to Ac) | 10ms | |||||||
Bypass without Battery Connected | Yes | |||||||
Max. Bypass Current | 30A | |||||||
Output/Inverter Pattern Specification | ||||||||
Model NS series | Model ( NS series ) | |||||||
1012 | 1024 | 2012 | 2024 | 3024 | 3048 | 5048E | 6048E | |
Nominal Output Capacity (VA) | 1000 | 2000 | 3000 | 5000 | 6000 | |||
Nominal Output Power (W) | 1000 | 2000 | 3000 | 5000 | 6000 | |||
Output Wave Form | Sine wave | |||||||
Power Factor | 0~1.0 | |||||||
Nominal Output Voltage (V) | 100VAC/110VAC/120VAC or 220VAC/230VAC/240VAC | |||||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz | |||||||
Automatic tracking main frequency(Hz) | Yes( start from the first connection ) 50Hz @48-54Hz, 60Hz @58-64Hz | |||||||
Output Voltage Regulation | ±10% rms | |||||||
Efficiency | >80% | |||||||
Overload Protection (SMPS load) | (110%< Load <125%) ±10%: No Output after 15mins, (125%< Load <150%) ±10%: No Output after 10S, Load>150% ±10%: No Output after 20S | |||||||
Surge ratings (10s) | 3000VA | 6000VA | 9000VA | 15000VA | 18000VA | |||
Motor Starting | 1HP | 2HP | 3HP | 5HP | 6HP | |||
Short Circuit protection | Current limit ( fault after 10s ) | |||||||
Circuit breaker Size | 30A | 30A | 50A | 50A | 50A | |||
Nominal DC Input Voltage | 12Vdc/ 24Vdc/48Vdc | |||||||
Minium Start Voltage | 10Vdc/20Vdc/40Vdc | |||||||
Low Voltage Alarm | 10.5Vdc ± 0.3Vdc for 12Vdc, 21.0Vdc ± 0.6Vdc for 24Vdc, 42Vdc± 0.6Vdc for 48Vdc | |||||||
Low Voltage Trip | 10.0Vdc ± 0.3Vdc for 12Vdc, 20.0vdc± 0.6Vdc for 24Vdc, 40Vdc± 0.6Vdc for 48Vdc | |||||||
High Voltage Alarm | 16Vdc ± 0.3Vdc for 12Vdc, 32Vdc ± 0.6Vdc for 24Vdc),64Vdc± 0.6Vdc for 48Vdc | |||||||
High Voltage reengage | Load ≤ 25W | |||||||
Size (MM) | 442*218*179mm | 598*218*179 | ||||||
Weight (Kg) | 18 | 20 | 22 | 38 | 40 | |||
Baykee reserves the right to change or modify product design, construction, specifications or materials without prior notice and without incurring any obligation to make such changes and modifications on Baykee products previously or subsequently sold. |