1kW-6kW home ups pure sine inverter circuit diagram , inverter ups
USD $100 - $1,000 /Piece
Min.Order:1 Piece
Foshan Baykee New Energy Technology Incorporated Company
Model(NS)
| Sine wave inverter | ||||||||||||||
1012 | 1024 | 2012 | 2024 | 3024 | 3048 | 5048 | 6048 | ||||||||
1000W | 1000W | 2000W | 2000W | 3000W | 3000W | 5000W | 6000W | ||||||||
DC12V | DC24V | DC12V | DC24V | DC24V | DC48V | DC48V | DC48V | ||||||||
Grid (Mails) mode specifications | |||||||||||||||
Input voltage waveform | Pure sine wave(mains or generator) | ||||||||||||||
Rated output voltage | 230Vac | ||||||||||||||
Low voltage protection | 184Vac±4% | ||||||||||||||
low voltage recovery point | 194Vac ±4% | ||||||||||||||
High voltage protection | 253Vac±4% | ||||||||||||||
High voltage recovery point | 243Vac±4% | ||||||||||||||
Max AC input voltage | 270Vrms | ||||||||||||||
Rated input frequency | 50Hz/ 60Hz (auto) | ||||||||||||||
Low voltage recovery point by frequency | 58+0.3Hz (60Hz); 48+0.3Hz(50Hz); | ||||||||||||||
Low voltage shut-off point by frequency | 57+0.3Hz (60Hz); 47+0.3Hz (50Hz); | ||||||||||||||
High voltage recovery point by frequency | 64+0.3Hz (60Hz); 54+0.3Hz (50Hz); | ||||||||||||||
High voltage shut off point by frequency | 65+0.3Hz (60Hz); 55+0.3Hz (50Hz); | ||||||||||||||
Output voltage waveform | Same with input waveform | ||||||||||||||
Overload protection | breaker on | ||||||||||||||
Short circuit protection | Breaker on | ||||||||||||||
Power efficiency | >95% | ||||||||||||||
Switching current | 30A | ||||||||||||||
Switching time (AC to DC) | 10ms | ||||||||||||||
Switching time(DC to AC) | 10ms | ||||||||||||||
Bypass switching current | yes | ||||||||||||||
Bypass Max load current | 30A | ||||||||||||||
Inverter mode specification | |||||||||||||||
Model (NS) | NS model | ||||||||||||||
1012 | 1024 | 2012 | 2024 | 3024 | 3048 | 5048 | 6048 | ||||||||
Output voltage waveform | Pure sine wave | ||||||||||||||
Rated output capacity(VA) | 1000 | 2000 | 3000 | 5000 | 6000 | ||||||||||
Rated output power(W) | 1000 | 2000 | 3000 | 5000 | 6000 | ||||||||||
PF | 0.9~1.0 | ||||||||||||||
Rated output voltage(V) | 230Vac | ||||||||||||||
Rated output frequency (Hz) | 50Hz ± 0.3Hz | ||||||||||||||
Auto track main frequency(Hz) | yes (from the first start) 50Hz @48-54Hz 60Hz @58-64Hz | ||||||||||||||
Output voltage range | ±10% rms | ||||||||||||||
Efficient | >80% | ||||||||||||||
Overload protection (SMPS load) | (110%<load capacity<125%) ±10%: after 15min cut off output voltage (125%<load capacity<150%) ±10%: after 10min cut off output voltage load capacity>150% ±10%: after 20 min cut off output voltage | ||||||||||||||
Peak capacity (10s) | 3000VA | 6000VA | 9000VA | 15000VA | 18000VA | ||||||||||
Start motor | 1HP | 2HP | 3HP | 5HP | 6HP | ||||||||||
| Current limit(10s after power off) |
| |||||||||||||
Breaker specification | 30A | 30A | 30A | 50A | 50A | ||||||||||
Rated DC input voltage | 12V/24V/48V | ||||||||||||||
Min DC voltage | 10V/20V | ||||||||||||||
Low-voltage alarm | 10.5Vdc±0.3Vdc(12V)/21.0Vdc±0.6Vdc(24V)/42.0Vdc±1.2Vdc(48V) | ||||||||||||||
auto cut off level when DC input voltage low | 10.0Vdc±0.3Vdc(12V)/20.0vdc±0.6Vdc(24V)/40.0Vdc±1.2Vdc(48V) | ||||||||||||||
Cut off level when Input over voltage alarm | 16.0Vdc±0.3Vdc(12V)/32.0Vdc±0.6Vdc(24V)/64.0Vdc±1.2Vdc(48V) | ||||||||||||||
Input over-voltage recovery | 15.5Vdc±0.3Vdc(12V)/31.0Vdc±0.6Vdc(12V)/62.0Vdc±1.2Vdc(48V) | ||||||||||||||
Power Saving | load <=25W |