infusion set assembly machine automatic bottle nitrogen filling machine gas injection
USD $1,000 - $90,000 /Set
Min.Order:1 Set
Hunan FE Pharmaceutical Machinery Co., Ltd.
manufacturers of glass washing machine, ultrasonic washing machine
pre-filled syringe filling and stoppering machine liquid filling machine
continuous washing machine,stability of glass bottle IV solution ultrasonic cleaners
high automation wash-fill infusion equipment automatic filling plant manufacturer
6KW washing and filling all in one machine bottling machineries
liquid glucose machines 380V filling,nitrogen filling and stoppering machine
Vacuum nitrogen filling and stoppering machine
Main application
Vacuum nitrogen filling and stoppering machine is suitable for glass IV solution products vacuuming,nitrogen filling,and stoppering etc.
Performance Characteristics
1.Adopts large capacity electromagnetic hopper,reduce the labor intensity.
2.Vacuum stoppering and mechanical positioning,only when the stoppers is in the accurate place it can go to the stoppering station,high qualified rate.
3.The machine uses the microcomputer frequency modulator to do the frequency speed adjustments.The capacity can be stepless speed regulated within the rated capacity with easy,no noise,safe and reliable characteristics;
4.Equipped with bottle mouth positioning units,good centering.Bottle enters continually,running stable,and high efficiencies.
5.Low residual oxygen after vacuuming and stoppering.( ensures less than 1.0%)
6.High automatic,can adjust the vacuuming time,nitrogen filling time and the number time of vacuuming and nitrogen filling.
Main Technical Parameter
Applicable size:100ml,250ml,500ml glass bottle,T rubber stopper;
Capacity:80-120 bottle/min(vacuuming and nitrogen filling);
Stopper supplying heads:16,Nitrogen filling heads:16,Vacuuming heads:16;
Electric capacity:3.5KW AC380 50Hz;
Nitrogen pressure:0.03--0.05MPa Nitrogen consumption:0--50ml/bottle;
Vacuum pump air suction amount:more than 200 m³/hour Air suction pressure:about 33mbar;
Residual oxygen:less than 1.0%;
Stoppering qualified rate:99%