Mean Well 1000w single output power supplies 48v/ 1000 ~ 3000W Front End Power System/1000w power supply with auxiliary power
USD $1 - $100 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
UL approved meanwell rcp-1u rack system 30kw 12v 180a power supply
Mean Well Power Control and Monitor System RCP-MU 19" Rack Power for RCP-1000
CE MEC approved meanwell rcp-1u rack system 30kw power supply 24v 120a
Original meanwell rcp-1u rack system 48v 3kw high power dc power supply
Mean Well 1U rack power system 7500W high power power supply with charger systerm
MODEL | RCP-1000-48 | |
OUTPUT
| DC VOLTAGE | 48V |
RATED CURRENT | 21A | |
CURRENT RANGE | 0 ~ 21A | |
RATED POWER | 1008W | |
RIPPLE&NOISE (max.) Note.2 | 300mVp-p | |
VOLTAGE ADJ. RANGE | 46.3~ 49.7V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE TIME | 1000ms, 60ms / 230VAC at full load | |
HOLD UP TIME (Typ. | 16ms/230VAC at full load | |
INPUT
| VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 89% | |
AC CURRENT (Typ.) | 11A/115VAC 5.5A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 50A | |
LEAKAGE CURRENT | <1.1mA / 230VAC | |
PROTECTION
| OVER LOAD
| 105 ~ 125% rated output power |
Protection type : Constant current limiting, unit will shut down after 3 sec. re-power on to recover | ||
OVER TEMPERATURE
| 75°C± 5°C (TSW:detect on heatsink of power transistor ) 85°C± 5°C (TSW2) detect on heatsink of power diode | |
Protection type : Shut down o/p voltage, re-power on to recover after temperature goes down | ||
OVER VOLTAGE | 52.8~ 64.8V | |
| Protection type : Shut down o/p voltage, re-power on to recover | |
FUNCTION
| AUXILIARY POWER | 5V @ 0.3A |
REMOTE ON/OFF CONTROL | By electrical signal or dry contact ON:short OFF:open | |
DC OK SIGNAL | The TTL signal out, refer to function manual | |
AC FAIL SIGNAL | The TTL signal out, refer to function manual | |
OUTPUT VOLTAGE TRIM | Adjustment of output voltage, possible between 90 ~ 110% of rated output | |
OVER TEMP WARNING | Logic " High" for over temperature warning, refer to function manual | |
ENVIRONMENT
| WORKING TEMP. | -20~+60°C (Refer to derating curve) |
WORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.02%/°C (0~50°C) | |
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC
| SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVACO/P-DC OK:0.5KVAC | |
EMC EMISSION | Compliance to EN55022(CISPR22), Class B,EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11,EN61000-6-2(EN50082-2), EN61204-3, heavy industry level, criteria A | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |
OTHERS
| MTBF | 43.4K hrs min. MIL-HDBK-217F (25 ) |
DIMENSION | 295*127*41mm (L*W*H) | |
PACKING | 1.91Kg; 6pcs/12.5Kg/1.04CUFT |