100w 36V LED driver/MeanWell100w 36v switching power supply/100W Single Output Switching Power Supply/power supplies 100w
USD $1 - $10 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
MODEL | HBG-100-36 | |
OUTPUT | DC VOLTAGE | 36V |
CONSTANT CURRENT OPERATION VOLTAGE | 21.6 ~ 36V | |
RATED CURRENT | 2.7A | |
RATED POWER | 97.2W | |
RIPPLE&NOISE (max.) Note.2 | 300mVp-p | |
CURRENT ADJ. RANGE | 1.62 ~ 2.7A | |
Can be adjusted by internal potentiometer A type only | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.0% | |
SETUP, RISE TIME | 2000ms,,80ms/ 230VAC 1000ms,80ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 12ms at full load 115VAC/230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.96/115VAC, PF>0.96230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |
EFFICIENCY (Typ.) | 91% | |
AC CURRENT (Typ.) | 1.1A / 115VAC 0.5A / 230VAC 0.45A / 277VAC | |
INRUSH CURRENT (Typ.) | COLD START 60A(twitdth=415μs,measured at50%ipeak) at 230VAC | |
MAX.LED DRIVE NUMBER ON MCB C TYPE 16A | 21units@230VAC | |
LEAKAGE CURRENT | <0.75mA / 277VAC | |
OVER CURRENT | 95~ 108% | |
Protection type : Constant current limiting, | ||
OVER TEMPERATURE | 95°C± 10°C (RTH1) | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER VOLTAGE | 41 ~ 49V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
ENVIRONMENT | WORKING TEMP. | -40~+60°C (Refer to derating curve) |
WORKING HUMIDITY | 20~95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+80°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | |
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Design refer to UL8750, EN61347-2-13 |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC | |
EMC EMISSION | Compliance to EN55015, EN61000-3-2 Class C (>60% load) ; EN61000-3-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge 4KV), criteria A | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |
OTHERS | MTBF | 300K hrs min. MIL-HDBK-217F (25 ) |
DIMENSION | Refer to mechanical specification | |
PACKING | 1.1Kg; 12pcs/15.2Kg/1.43CUFT | |
NOTE | 1 All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2.. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated witha 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5.Derating may be needed under low input voltage. Please check the static characteristics for more details. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
|